The goal of this research is to study two-port network of wavelet transform processor (WTP) using surface acoustic wave (SAW) devices and its application. The motive was prompted by the inconvenience of the long research and design cycle and the huge research funding involved with traditional method in this field, which were caused by the lack of the simulation and emulation method of WTP using SAW devices. For this reason, we introduce the two-port network analysis tool, which has been widely used in the design and analysis of SAW devices with uniform interdigital transducers (IDTs). Because the admittance parameters calculation formula of the two-port network can only be used for the SAW devices with uniform IDTs, this analysis tool cannot be directly applied into the design and analysis of the processor using SAW devices, whose input interdigital transducer (IDT) is apodized weighting. Therefore, in this paper, we propose the channel segmentation method, which can convert the WTP using SAW devices into parallel channels, and also provide with the calculation formula of the number of channels, the number of finger pairs and the static capacitance of an interdigital period in each parallel channel firstly. From the parameters given above, we can calculate the admittance parameters of the two port network for each channel, so that we can obtain the admittance parameter of the two-port network of the WTP using SAW devices on the basis of the simplification rule of parallel two-port network. Through this analysis tool, not only can we get the impulse response function of the WTP using SAW devices but we can also get the matching circuit of it. Large numbers of studies show that the parameters of the two-port network obtained by this paper are consistent with those measured by network analyzer E5061A, and the impulse response function obtained by the two-port network analysis tool is also consistent with that measured by network analyzer E5061A, which can meet the accuracy requirements of the analysis of the WTP using SAW devices. Therefore the two-port network analysis tool discussed in this paper has comparatively higher theoretical and practical value.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2017.04.017DOI Listing

Publication Analysis

Top Keywords

two-port network
36
wtp devices
20
analysis tool
20
network analysis
16
network
11
devices
10
two-port
9
network wavelet
8
wavelet transform
8
transform processor
8

Similar Publications

Frequency response measurement, or the forward transmission coefficient (S) measurement for a two-port network, is the key function of a vector network analyzer (VNA). In this paper, a broadband and high dynamic range (DR) microwave S parameter measurement scheme based on an optical phase-locked loop (OPLL) is proposed. By heterodyning two phase-locked hybrid integrated ultra-narrow linewidth lasers, a microwave signal with low phase noise and spurious level is generated as the incident signal and reference signal, and the signal frequency can be easily manipulated over a wide range by tuning the master laser wavelength.

View Article and Find Full Text PDF

This paper presents a two-port microstrip patch antenna system with compact size and high isolation for full-duplex and multiple-input-multiple-output (MIMO) applications. The proposed miniaturization approach is to employ compact microstrip patch antenna and decoupling network as well. Here, two quarter-wavelength patch antennas are arranged in the H-plane coupled configuration with element spacing of about 0.

View Article and Find Full Text PDF

A technique for solving the one-port closed coaxial transmission line sample holder scattering equation for complex permittivity inversion for lossy materials is presented. A non-linear least-squares procedure is used for the determination of parameters for the specification of the spectral functional form of the complex permittivity. The method allows for accurate retrieval of many low- and high-permittivity dielectric materials in the frequency range of 1 GHz to 3 GHz inserted into the coaxial cell.

View Article and Find Full Text PDF

Rotational Doppler shift of a circularly polarized wave impinging normally on a rotating anisotropic surface, causes scattered waves with frequency shift equals twice the surface rotation frequency. We show that virtual rotational Doppler shift can be realized in transmission line platforms through a time-varying junction. In a system consisting of a pair of decoupled but identical transmission lines, voltage waves with a 90-degree phase difference between the two lines mimic a circularly polarized wave.

View Article and Find Full Text PDF

Stroke is a leading cause of mortality and disability. Emergent diagnosis and intervention are critical, and predicated upon initial brain imaging; however, existing clinical imaging modalities are generally costly, immobile, and demand highly specialized operation and interpretation. Low-energy microwaves have been explored as a low-cost, small form factor, fast, and safe probe for tissue dielectric properties measurements, with both imaging and diagnostic potential.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!