A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Usability of a home-based test for the measurement of fecal calprotectin in asymptomatic IBD patients. | LitMetric

Unlabelled: The aim of our work was to test the usability of fecal calprotectin (FC) home-based test in inflammatory bowel disease (IBD) patients.

Methods: IBD patients were prospectively recruited. They had to measure FC with a dedicated tool and smartphone application, 5 times at two weeks intervals over an 8 weeks period. They had to fill in a usability questionnaire at the first and the last FC measurement. A System Usability Scale (SUS: 0-100) and the Global Score of Usability (GSU: 0-85) were calculated. FC was also centrally measured by ELISA.

Results: Fifty-eight patients were recruited. Forty-two performed at least one FC measurement and 27 performed all the FC requested measurements. The median (IQR) SUS (0-100) at the first and last use were 85 (78-90) and 81 (70-88), respectively; the median (IQR) GSU (0-85) at the first and last use were 74 (69-80) and 77 (68-83), respectively. Adherence to the planned measurements and usability of the tool were higher in females and in less severe disease. The intra-class correlation coefficient between home-based and centrally measured FC was 0.88.

Conclusion: The adherence to home-based measurement of FC was fair. Usability scores for the home-based test were high. There was a good correlation with the centrally measured FC by ELISA.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dld.2017.05.009DOI Listing

Publication Analysis

Top Keywords

home-based test
12
centrally measured
12
fecal calprotectin
8
ibd patients
8
sus 0-100
8
gsu 0-85
8
median iqr
8
usability
7
usability home-based
4
test
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!