Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The placement of a percutaneous endoscopic gastrostomy (PEG) in a patient with a pre-existing ventriculoperitoneal shunt is generally regarded as safe. A critical but often overlooked technical consideration is confirmation of the course of the distal shunt tube prior to PEG insertion. We present the case of a 4-month-old male infant with shunted hydrocephalus who experienced shunt malfunction due to perforation of the distal shunt tubing after PEG placement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5449579 | PMC |
http://dx.doi.org/10.14309/crj.2017.75 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!