Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5455030PMC
http://dx.doi.org/10.4103/ijccm.IJCCM_59_17DOI Listing

Publication Analysis

Top Keywords

overestimation cardiac
4
cardiac output
4
output bent
4
bent pulmonary
4
pulmonary artery
4
artery catheter
4
overestimation
1
output
1
bent
1
pulmonary
1

Similar Publications

Feasibility of on-site CT-FFR analysis on cardiac photon-counting CT in evaluation of hemodynamically significant stenosis in comparison to invasive catheter angiography.

Eur J Radiol

January 2025

Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:

Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.

View Article and Find Full Text PDF

Updating the Scottish national cardiovascular risk score: ASSIGN version 2.0.

Heart

January 2025

The George Institute for Global Health, School of Public Health, Imperial College London, London, UK.

Background: The Assessing cardiovascular risk using Scottish Intercollegiate Guidelines Network (ASSIGN) risk score, developed in 2006, is used in Scotland for estimating the 10-year risk of first atherosclerotic cardiovascular disease (ASCVD). Rates of ASCVD are decreasing, and an update is required. This study aimed to recalibrate ASSIGN (V.

View Article and Find Full Text PDF

Arterial compliance (AC) is an important cardiovascular parameter characterizing mechanical properties of arteries. AC is significantly influenced by arterial wall structure and vasomotion, and it markedly influences cardiac load. A new method, based on a two-element Windkessel model, has been recently proposed for estimating AC as the ratio of the time constant T of the diastolic blood pressure decay and peripheral vascular resistance derived from clinically available stroke volume measurements and selected peripheral blood pressure parameters which are less prone to peripheral distortions.

View Article and Find Full Text PDF

To compare the impact of manual right arm blood pressure measurement with computer-controlled blood pressure meter (CCBPM) on the detection rate of hypertension among elderly individuals. This was a cross-sectional study. Elderly residents undergoing routine health check-up in a village in Jiangxi Province from April to June 2024 were enrolled.

View Article and Find Full Text PDF

Background: The integration of procedure-specific risks into preoperative patient assessment and optimization are crucial aspects of perioperative care. However, data on internists' knowledge of surgical and anesthetic principles and practices are limited. We thus sought to identify internists' knowledge gaps in terms of surgical- and anesthetic-specific risk factors and characteristics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!