AI Article Synopsis

Article Abstract

We compared transcranial Doppler (TCD) with transesophageal echocardiography (TEE) and transthoracic echocardiography (TTE) for the detection of right to left communication (RLC) in the heart. All patients explored from 2013 to 2016 in a vascular medicine unit to detect RLC by TCD were included. Right to left communication was detected by TCD monitoring for microembolic signals after intravenous injection of agitated 5% glucose and air. One hundred one patients were explored for RLC by TCD, 64 by TEE (not possible in 10, bubble injection in 51), and 93 by TTE because of unexplained stroke or arterial thrombosis (51 males, 50 females, age 51.0 ± 15.8 years) (bubble injection in 35). Fifty-three patients were positive after TCD (TEE: 4 negative, TTE: 7 negative). Of the negative patients after TCD, none was positive for TEE and 1 was positive for TTE with no evidence of patent foramen ovale. Transcranial Doppler was sensitive to detect RLC, even in patients with negative TTE or TTE. A negative TEE did not exclude RLC demonstrated by TCD. Transcranial Doppler might be proposed as first line to detect RLC.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0003319717712356DOI Listing

Publication Analysis

Top Keywords

transcranial doppler
16
left communication
12
detect rlc
12
transesophageal echocardiography
8
patients explored
8
rlc tcd
8
tcd tee
8
bubble injection
8
negative tte
8
tte negative
8

Similar Publications

A reduction in cerebral blood flow (CBF) has been observed during spaceflight and bed rest. We aimed to examine the magnitude and regional heterogeneity of the decrease in CBF during bed rest compared to posture changes on Earth. Seventeen participants (age, 29 ± 9 years, 7 females) were studied in the upright and supine posture and over 3 days of bed rest.

View Article and Find Full Text PDF

The clinical impact of recent amphetamine exposure in aneurysmal subarachnoid hemorrhage patients.

Front Neurol

January 2025

Department of Neurology, Weill Institute for Neurosciences, University of California, San Francisco, San Francisco, CA, United States.

Background: Amphetamines possess sympathomimetic properties that can affect cerebral vasculature though conflicting reports exist about their effect on vasospasm risk and clinical outcomes in aneurysmal subarachnoid hemorrhage. This study aimed to characterize the impact of recent amphetamine use on vasospasm development in aneurysmal subarachnoid hemorrhage as well as neurological outcomes.

Methods: We retrospectively screened 441 consecutive patients admitted with a diagnosis of subarachnoid hemorrhage who underwent at least one cerebral digital subtraction angiogram.

View Article and Find Full Text PDF

Background: Ancillary tests are often used in the determination of death by neurologic criteria (DNC), especially when the clinical examination is inconclusive. DNC is widely accepted, as defined by the comprehensive report of the World Brain Death Project. However, there are several medical, legal, religious, ethical, and social controversies.

View Article and Find Full Text PDF

Mean middle cerebral artery velocity (MCAv) and the pulsatility index (PI), at rest and in response to exercise, are important markers of cerebrovascular health status in middle-aged adults, when vascular decline assumes substantial relevance. Thus, this study aimed to describe and compare the responses of MCAv and PI to incremental exercise. Two hundred and forty-eight volunteers (50-58 years, 55% women) completed a ramp test on a cycle-ergometer.

View Article and Find Full Text PDF

Artificial Intelligence in Transcranial Doppler Ultrasonography.

Curr Med Imaging

January 2025

UOC Neurologia e Rete Stroke Metropolitana, Istituto delle Scienze Neurologiche di Bologna, Italy.

Transcranial Doppler is an instrumental ultrasound method capable of providing data on various brain pathologies, in particular, the study of cerebral hemodynamics in stroke, quickly, economically, and with repeatability of the data themselves. However, literature reviews from clinical studies and clinical trials reported that it is an operator-dependent method, and the data can be influenced by external factors, such as noise, which may require greater standardization of the parameters. Artificial intelligence can be utilized on transcranial Doppler to increase the accuracy and precision of the data collected while decreasing operator dependencies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!