AI Article Synopsis

  • * A study explored the impact of side holes in double J stents on urine flow, specifically using models that mimic human anatomy instead of straight ureters.
  • * Findings revealed that side holes improved urine flow rates in cases of ureteral stenosis, particularly as the severity of the stenosis increased, although their angular positioning did not influence the flow rates.

Article Abstract

Ureteral stenosis presents with a narrowing in the ureter, due to an intrinsic or extrinsic ureteral disease, such as ureter cancer or retroperitoneal fibrosis. The placement of a double J stent in the upper urinary system is one of the most common treatments of ureteral stenosis, along with the insertion of a percutaneous nephrostomy tube into the renal pelvis. The effect that the side holes in a double J stent have on urine flow has been evaluated in a few studies using straight ureter models. In this study, urine flow through a double J stent's side holes was analyzed in curved ureter models, which were based on human anatomy. In ureteral stenosis, especially in severe ureteral stenosis, a stent with side holes had a positive effect on the luminal and total flow rates, compared with the rates for a stent without side holes. The more side holes a stent has, the greater the luminal and total flow rates. However, the angular positions of the side holes did not affect flow rate. In conclusion, the side holes in a double J stent had a positive effect on ureteral stenosis, and the effect became greater as the ureteral stenosis became more severe.

Download full-text PDF

Source
http://dx.doi.org/10.3233/THC-171307DOI Listing

Publication Analysis

Top Keywords

side holes
32
ureteral stenosis
28
double stent
16
urine flow
12
holes double
12
side
8
holes
8
ureteral
8
ureter models
8
stenosis severe
8

Similar Publications

Open-ended urethral catheters reduce catheter obstruction after hypospadias repair.

Front Pediatr

December 2024

Department of Pediatric Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.

Backgrounds: Urethral catheter obstruction is a notable issue that pediatric patients with hypospadias may encounter in the early postoperative period. This retrospective study aims to assess the efficacy of open-ended urethral catheters with 2 side holes in mitigating catheter obstruction in pediatric patients following hypospadias repair.

Materials And Methods: The clinical data of pediatric patients who underwent hypospadias repair surgery from January 2021 to October 2023 were retrospectively collected.

View Article and Find Full Text PDF

Development and Evaluation of a Novel Drainage Cannula for Venoarterial Extracorporeal Membrane Oxygenation.

ASAIO J

December 2024

From the Cardio-Respiratory Engineering and Technology Laboratory, Mechanical and Aerospace Engineering, Monash University, Clayton, Victoria, Australia.

A critical factor in thrombus formation during venoarterial extracorporeal membrane oxygenation (VA ECMO) is prothrombotic flow dynamics generated by the drainage cannula's design. This study aimed to create and evaluate a novel drainage cannula design which optimized blood flow dynamics to reduce thrombus formation. Computational fluid dynamics (CFD) was used to iteratively vary drainage cannula design parameters such as inner wall shape and side hole shape.

View Article and Find Full Text PDF

Carrier Recirculation Induced Ultrasensitive Photodetectors of InSe/CdTe Heterostructure Featuring an Interfacial Holes Layer.

Small

December 2024

State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, No.500 Yutian Road, Shanghai, 200083, P. R. China.

Photodetectors (PDs) based on mix-dimensional heterojunctions (MDHJs) built from 2D layered materials and covalent-bonded semiconductors show the prospect of compensating the intrinsic weakness of 2D materials to realize their full potential. However, there is an open issue to improve the temporal response of PDs while maintaining high gain and sensitivity. Herein, photoconductive type MDHJs PDs with 2D InSe and covalent-bonded CdTe thin film are designed and fabricated in which InSe is the active layer and CdTe is the medium gain one.

View Article and Find Full Text PDF

Development of Dopant-Free N,N'-Bicarbazole-Based Hole Transport Materials for Efficient Perovskite Solar Cells.

Int J Mol Sci

December 2024

Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.

Efficient and stable hole-transport material (HTM) is essential for enhancing the efficiency and stability of high-efficiency perovskite solar cells (PSCs). The commonly used HTMs such as spiro-OMeTAD need dopants to produce high efficiency, but those dopants degrade the perovskite film and cause instability. Therefore, the development of dopant-free N,N'-bicarbazole-based HTM is receiving huge attention for preparing stable, cost-effective, and efficient PSCs.

View Article and Find Full Text PDF

Generally, the extraction method has a great influence on the quality of pectin. However, there is little study on the effect of extraction method on the properties of fruit pulp pectin (CAPP). Accordingly, the physicochemical, structural, and functional properties of CAPP extracted by hot water (HWE), hydrochloric acid (HAE), ultrasound (UAE), and ultrahigh pressure (UPE) were investigated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!