Optical coherence tomography (OCT) is an established catheter-based imaging modality for the assessment of coronary artery disease and the guidance of stent placement during percutaneous coronary intervention. Manual analysis of large OCT datasets for vessel contours or stent struts detection is time-consuming and unsuitable for real-time applications. In this study, a fully automatic method was developed for detection of both vessel contours and stent struts. The method was applied to in vitro OCT scans of eight stented silicone bifurcation phantoms for validation purposes. The proposed algorithm comprised four main steps, namely pre-processing, lumen border detection, stent strut detection, and three-dimensional point cloud creation. The algorithm was validated against manual segmentation performed by two independent image readers. Linear regression showed good agreement between automatic and manual segmentations in terms of lumen area (r>0.99). No statistically significant differences in the number of detected struts were found between the segmentations. Mean values of similarity indexes were >95% and >85% for the lumen and stent detection, respectively. Stent point clouds of two selected cases, obtained after OCT image processing, were compared to the centerline points of the corresponding stent reconstructions from micro computed tomography, used as ground-truth. Quantitative comparison between the corresponding stent points resulted in median values of ~150 μm and ~40 μm for the total and radial distances of both cases, respectively. The repeatability of the detection method was investigated by calculating the lumen volume and the mean number of detected struts per frame for seven repeated OCT scans of one selected case. Results showed low deviation of values from the median for both analyzed quantities. In conclusion, this study presents a robust automatic method for detection of lumen contours and stent struts from OCT as supported by focused validation against both manual segmentation and micro computed tomography and by good repeatability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456060 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0177495 | PLOS |
Ann Thorac Surg Short Rep
June 2024
Department of Cardiothoracic Surgery, New York University Langone Medical Center, New York, New York.
We describe a rare but interesting complication of totally endoscopic robotic mitral valve repair in a patient with severe mitral regurgitation. The mitral valve was repaired robotically by standard techniques, and the intraoperative transesophageal echocardiogram demonstrated no residual mitral regurgitation. However, there was unexpected hypokinesia of the posterior and lateral walls of the left ventricle, with subsequent electrocardiography showing acute ST elevations of the lateral segment.
View Article and Find Full Text PDFJ Clin Med
October 2024
Department of Neurosurgery, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, North Shore University Hospital, Manhasset, NY 11030, USA.
: The endovascular treatment of complex intracranial aneurysms, such as wide-neck aneurysms (WNAs), remains a challenge. More established endovascular techniques, which include balloon-assisted coiling, stent-assisted coiling, and flow diversion, all have their drawbacks. Intrasaccular flow disruptor devices have emerged as a useful tool for the neurointerventionalist.
View Article and Find Full Text PDFCardiovasc Eng Technol
December 2024
Department of Pediatrics, Stanford University, Stanford, CA, USA.
Purpose: Angioplasty with stent placement is a widely used treatment strategy for patients with stenotic blood vessels. However, it is often challenging to predict the outcomes of this procedure for individual patients. Image-based computational fluid dynamics (CFD) is a powerful technique for making these predictions.
View Article and Find Full Text PDFClin Endosc
November 2024
Division of Gastroenterology, Department of Internal Medicine, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Background/aims: Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods: All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing.
Front Cardiovasc Med
August 2024
Department of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.
Background: Pulsed-field ablation (PFA) technique is a nonthermal ablation technique. No study has yet evaluated the effect of the positional relationship between the ablation electrode (AE) and the coronary metal stent (CMS) on the electric field distribution and temperature distribution in epicardial ablation. Our study aimed to evaluate the effect of the CMS on the electric field as well as the temperature distribution in different models.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!