The Oxford medial unicompartmental knee is designed fully congruent, with the purpose of maintaining a large contact-area throughout motion and minimize wear. No other study has investigated this design feature in-vivo. We aimed to evaluate if contact-loss was introduced between the articulating surfaces of the Oxford medial unicompartmental knee during bicycle- and step-cycle motion, and whether this correlated with essential implant parameters, such as polyethylene (PE) wear, knee-loadings, and clinical outcome. To study contact-loss, 15 patients (12 males, mean age 69 years) with an Oxford medial unicompartmental knee (7 cemented, mean follow-up 4.4 years) were examined with use of dynamic radiostereometry (RSA) (10 frames/s). PE wear was measured from static RSA and clinical outcome was evaluated with American Knee Society Score (AKSS) and Oxford Knee Score (OKS). Data on knee-loadings were acquired from the literature. Contact-loss was deteced in all patients during both exercises, and the trend of contact-loss correlated with the knee-loadings. Median contact-loss was 0.8 mm (95%PI: 0.3; 1.5) for bicycle motion and 0.3 mm (95%PI: 0.24; 0.35) for step-cycle motion, and did not correlate with the PE wear rate of mean 0.06 mm/year. Possible in-congruency was seen in three patients. Clinical outcome scores correlated with contact-loss during step-cycle motion. In conclusion, contact-loss was seen in all patients indicating a clinical tolerance during load. Contact-loss followed the knee-loadings, which could explain why no correlation was seen with PE wear, as an increase in load was acommadated by an increase in contact-area (contact-loss reduction). The size of contact-loss may reflect clinical outcome. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:357-364, 2018.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.23625DOI Listing

Publication Analysis

Top Keywords

oxford medial
16
medial unicompartmental
16
step-cycle motion
16
clinical outcome
16
unicompartmental knee
12
contact-loss
11
contact-loss step-cycle
8
bicycle motion
8
contact-loss patients
8
motion
7

Similar Publications

Introduction: Total knee replacements are becoming more prevalent. There is still a lot of controversy regarding patellar resurfacing. Surgeons advocating for resurfacing state reduced risk for anterior knee pain and need for future revision surgery.

View Article and Find Full Text PDF

High tibial osteotomy (HTO) is a widely used procedure for delaying knee arthroplasty, correcting alignment, and relieving symptoms in patients with knee osteoarthritis. Recently, proximal fibular osteotomy (PFO) has emerged as a less invasive and more cost-effective alternative. This study compares the outcomes of HTO and PFO to evaluate whether PFO can deliver results comparable to HTO in similar patient populations.

View Article and Find Full Text PDF

Multi-level encoding of reward, effort, and choice across the frontal cortex and basal ganglia during cost-benefit decision-making.

Cell Rep

January 2025

Medical Research Council Brain Network Dynamics Unit, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Electronic address:

Adaptive value-guided decision-making requires weighing up the costs and benefits of pursuing an available opportunity. Though neurons across frontal cortical-basal ganglia circuits have been repeatedly shown to represent decision-related parameters, it is unclear whether and how this information is coordinated. To address this question, we performed large-scale single-unit recordings simultaneously across 5 medial/orbital frontal and basal ganglia regions as rats decided whether to pursue varying reward payoffs available at different effort costs.

View Article and Find Full Text PDF

Background: In medial mobile-bearing unicompartmental knee arthroplasty (MB-UKA), the position of the bearing does not correspond to the planned position which will increasing the risk of bearing dislocation. This study aimed to explore the relationship between the malposition of the femoral and tibial components and the phenomenon of bearing deviation using postoperative radiological measurements.

Methods: One hundred twenty patients who underwent mobile-bearing uni-compartmental knee arthroplasty (MB-UKA) at our hospital between January and August 2023 were enrolled in this retrospective study.

View Article and Find Full Text PDF

Background: Previous clinical studies suggest that preserving the anterior cruciate ligament (ACL) is crucial for stable knee motion and long-term longevity of the reconstructed knee. The ACL damage or loss often occurs in advanced medial osteoarthritis (OA). This study aimed to investigate the correlation between ACL damage and varus deformity progression as a risk factor for ACL tears in knee OA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!