A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Calculation algorithms alter the breath-by-breath gas exchange values when abrupt changes in ventilation occur. | LitMetric

The automatic metabolic units calculate breath-by-breath gas exchange from the expiratory data only, applying an algorithm ('expiration-only' algorithm) that neglects the changes in the lung gas stores. These last are theoretically taken into account by a recently proposed algorithm, based on an alternative view of the respiratory cycle ('alternative respiratory cycle' algorithm). The performance of the two algorithms was investigated where changes in the lung gas stores were induced by abrupt increases in ventilation above the physiological demand. Oxygen, carbon dioxide fractions and ventilatory flow were recorded at the mouth in 15 healthy subjects during quiet breathing and during 20-s hyperventilation manoeuvres performed at 5-min intervals in resting conditions. Oxygen uptakes and carbon dioxide exhalations were calculated throughout the acquisition periods by the two algorithms. Average ventilation amounted to 6·1 ± 1·4 l min during quiet breathing and increased to 41·8 ± 27·2 l min during the manoeuvres (P<0·01). During quiet breathing, the two algorithms provided overlapping gas exchange data and noise. Conversely, during hyperventilation, the 'alternative respiratory cycle' algorithm provided significantly lower gas exchange data as compared to the values yielded by the 'expiration-only' algorithm. For the first breath of hyperventilation, the average values provided by the two algorithms amounted to 0·37 ± 0·34 l min versus 0·96 ± 0·73 l min for O uptake and 0·45 ± 0·36 l min versus 0·80 ± 0·58 l min for exhaled CO (P<0·001 for both). When abrupt increases in ventilation occurred, such as those arising from a deep breath, the 'alternative respiratory cycle' algorithm was able to halve the artefactual gas exchange values as compared to the 'expiration-only' approach.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cpf.12444DOI Listing

Publication Analysis

Top Keywords

breath-by-breath gas
8
gas exchange
8
changes lung
8
lung gas
8
gas stores
8
carbon dioxide
8
quiet breathing
8
calculation algorithms
4
algorithms alter
4
alter breath-by-breath
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!