Introduction: The organ epididymis is secured the name considering it functioned as an appendix to the testis; earlier testis was called as didymi. Regarding the length of human epididymis, several values are attributed by different authors. The present study was aimed to find out the pattern, total length and inner surface area of human epididymis.

Materials And Methods: The study was conducted by employing microsurgical procedures on five testes from unclaimed human dead bodies.

Results: Caput was formed by few tubes interconnecting at three levels. These tubes led to corpus, which in turn was having more number of tubes interconnecting at different levels. Tubules were many looking like a mesh. United tubes of corpus form the single tube to form cauda. Epididymis length was 30.48 cm. Inner surface area was 818.16 mm2.

Conclusions: Reported values of others seem to be a modified version from that of animals. Authors believe that organic revolutionary changes in man led to a reduction in the length of epididymis.

Download full-text PDF

Source
http://dx.doi.org/10.5301/uj.5000229DOI Listing

Publication Analysis

Top Keywords

inner surface
12
surface area
12
human epididymis
8
pattern total
8
total length
8
length inner
8
tubes interconnecting
8
length
5
human
4
epididymis structural
4

Similar Publications

Slip flow, a fluid flow enhanced in comparison to that calculated using continuum equations, has been reported for many nanopores, mostly those with hydrophobic surfaces. We investigated the flow of water, hexane, and methanol through hydrophilic nanopores in silica colloidal crystals. Three silica sphere sizes were used to prepare the crystals: 150 ± 30, 500 ± 40, and 1500 ± 100 nm.

View Article and Find Full Text PDF

Purpose: This study aims to evaluate the effects of taper angle and the number of insertion-removal cycles on the retention force of 4 mol% yttria partially stabilized zirconia (4Y-PSZ) double crowns over time.

Materials And Methods: Primary and secondary crowns were fabricated using 4Y-PSZ with taper angles of 2°, 4°, and 6° (n=15). Retention force during crown removal was measured after applying 50-N and 100-N loads.

View Article and Find Full Text PDF

Background/purpose: Titanium (Ti) is extensively used in dental and orthopedic implants due to its excellent mechanical properties. However, its smooth and biologically inert surface does not support the ingrowth of new bone, and Ti ions may have adverse biological effects. The purpose is to improve the corrosion resistance of titanium and create a 3D structured coating to enhance osseointegration through a very simple and fast surface treatment.

View Article and Find Full Text PDF

Dentin hypersensitivity is primarily caused by the exposure of dentinal tubules due to various factors, so the key to treatment is to effectively seal these exposed tubules. However, traditional dentinal tubule sealants used in clinical practice often fail to adhere securely to the tubule surface when exposed to external stimuli, resulting in a recurrence of sensitivity. In this study, we developed a silicon micromotor that moved autonomously and loaded with silver nanoparticles and a photosensitive adhesive for dentin sensitivity therapy.

View Article and Find Full Text PDF

Severe acute graft-versus-host disease (GVHD) can occur during allogeneic hematopoietic stem cell transplantation (allo-HSCT), causing considerable morbidity and mortality. Although several biomarkers have been reported for predicting acute GVHD, they are often difficult to measure in routine clinical practice. Recently, three-dimensional computed tomography (3D-CT) has been used to quantify the detailed bronchial structure, which might correlate with acute GVHD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!