Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Periprosthetic femoral shaft fractures are a significant complication after total hip arthroplasty (THA). Plate osteosynthesis has been the mainstay of treatment around well-fixed stems. Nonunions are a rare and challenging complication of this fixation method. We report the outcomes of a novel orthogonal plating surgical technique for Vancouver B1 and C-type periprosthetic fractures that previously failed open reduction internal fixation (ORIF).
Methods: A retrospective review identified all patients with Vancouver B1/C THA periprosthetic femoral nonunions from 2010 to 2015. Exclusion criteria included open fractures and periprosthetic infections. The technique utilised a mechanobiologic strategy of atraumatic exposure, resection of necrotic tissue, bone grafting with adjuvant bone morphogenetic protein (BMP) and revision open reduction internal fixation with orthogonal plate osteosynthesis.
Results: 6 Vancouver B1/C periprosthetic femoral nonunions were treated. 5 patients were female with an average age of 80.3 years (range 72-91 years). The fractures occurred at a mean of 5.8 years (range 1-10 years) from their initial arthroplasty procedure. No patients underwent further revision surgery; there were no perioperative complications. All patients had a minimum of 11 months follow-up (mean 18.6, range 11-36 months). All fractures achieved osseous union, defined as solid bridging callus over at least 2 cortices and pain free, independent ambulation, at an average of 24.4 weeks (range 6.1-39.7 weeks).
Conclusions: This is the 1st series describing orthogonal locked compression plating using modern implants for periprosthetic femoral nonunions. This technique should be considered in periprosthetic femur fracture nonunions around a well-fixed stem.