A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Orthogonal plating of Vancouver B1 and C-type periprosthetic femur fracture nonunions. | LitMetric

Background: Periprosthetic femoral shaft fractures are a significant complication after total hip arthroplasty (THA). Plate osteosynthesis has been the mainstay of treatment around well-fixed stems. Nonunions are a rare and challenging complication of this fixation method. We report the outcomes of a novel orthogonal plating surgical technique for Vancouver B1 and C-type periprosthetic fractures that previously failed open reduction internal fixation (ORIF).

Methods: A retrospective review identified all patients with Vancouver B1/C THA periprosthetic femoral nonunions from 2010 to 2015. Exclusion criteria included open fractures and periprosthetic infections. The technique utilised a mechanobiologic strategy of atraumatic exposure, resection of necrotic tissue, bone grafting with adjuvant bone morphogenetic protein (BMP) and revision open reduction internal fixation with orthogonal plate osteosynthesis.

Results: 6 Vancouver B1/C periprosthetic femoral nonunions were treated. 5 patients were female with an average age of 80.3 years (range 72-91 years). The fractures occurred at a mean of 5.8 years (range 1-10 years) from their initial arthroplasty procedure. No patients underwent further revision surgery; there were no perioperative complications. All patients had a minimum of 11 months follow-up (mean 18.6, range 11-36 months). All fractures achieved osseous union, defined as solid bridging callus over at least 2 cortices and pain free, independent ambulation, at an average of 24.4 weeks (range 6.1-39.7 weeks).

Conclusions: This is the 1st series describing orthogonal locked compression plating using modern implants for periprosthetic femoral nonunions. This technique should be considered in periprosthetic femur fracture nonunions around a well-fixed stem.

Download full-text PDF

Source
http://dx.doi.org/10.5301/hipint.5000500DOI Listing

Publication Analysis

Top Keywords

periprosthetic femoral
16
femoral nonunions
12
orthogonal plating
8
vancouver c-type
8
periprosthetic
8
c-type periprosthetic
8
periprosthetic femur
8
femur fracture
8
fracture nonunions
8
open reduction
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!