Nondestructive evaluation using shearography requires a way to stress the inspection target. This technique is able to directly measure the displacement gradient distribution on the object surface. Shearography visualizes the internal structural damages as the anomalous pattern in the shearograpic fringe pattern. A piezoelectric (PZT) excitation system is able to generate loadings in the vibrational, acoustic, and ultrasonic regimes. In this paper, we propose a PZT-excited stroboscopic shearography. The PZT excitation could generate vibrational loading, a stationary wavefield, and a nonstationary propagation wave to fulfill the external loading requirement of shearography. The sweeping of the PZT excitation frequency, the formation of a standing wave, and a small shearing to suppress the incident wave were powerful controllable tools to detect the defects. The sweeping of the PZT excitation frequency enabled us to determine one of the defect-sensitive frequencies almost in real time. In addition, because the defect sensitive frequencies always existed in wide and plural ranges, the risk of the defect being overlooked by the inspector could be alleviated. The results of evaluation using stroboscopic shearography showed that an artificial 20 mm-diameter defect could be visualized at the excitation frequencies of 5-8 kHz range and 12.5-15.5 kHz range. This technique provided full field reliable and repeatable inspection results. Additionally, the proposed method overcame the important drawback of the time-averaged shearography, being required to identify the resonance vibration frequency sensitive to the defect.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4981938DOI Listing

Publication Analysis

Top Keywords

pzt excitation
16
stroboscopic shearography
12
pzt-excited stroboscopic
8
nondestructive evaluation
8
sweeping pzt
8
excitation frequency
8
khz range
8
shearography
7
excitation
5
development pzt-excited
4

Similar Publications

The fluorescence intensity ratio (FIR) approach, which relies on thermally coupled levels (TCLs), is significantly important for optical thermometry at room temperature and above, but was found to be impractical for low temperature sensing due to limited population density (thermal) or lack of spectrum at extremely low temperatures. Herein, we report a wide temperature range (12-673 K) sensing capability of the PbZrTiO:Er/Yb (C1:PZT) phosphor utilising the bandwidth of Stark sublevel split near-infrared (NIR) emission bands as one sensing parameter and FIR as another. Motivated by our previous studies on upconversion (UC) and the promising thermometry performance of the C1:PZT phosphor for real time nanothermometer monitoring (using visible TCLs), this work extends to the same thermometry application using UC-NIR emission as TCLs.

View Article and Find Full Text PDF

The actuator is a critical component of the micromanipulator. By utilizing the properties of expansion and contraction, the piezoelectric actuator enables the manipulator to handle and grasp miniature objects during micromanipulation. However, in piezoelectric ceramic disc actuators with conventional surface electrode configurations, the actuating force generated in the radial direction is relatively limited.

View Article and Find Full Text PDF

Piezoelectric sensors hold immense potential in structural health monitoring (SHM) applications. However, their performance can be deteriorated by defects and extreme weathering. Therefore, diagnosing the sensor before implementation is very crucial.

View Article and Find Full Text PDF

Chirp excitation for natural frequency optical coherence elastography.

Biomed Opt Express

October 2024

Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China.

Optical coherence elastography (OCE) has recently been used to characterize the natural frequencies of delicate tissues (e.g., the human cornea) with sub-micron tissue oscillation magnitudes.

View Article and Find Full Text PDF

This paper reports a 30×12 row-column (RC) addressed flexible piezoelectric micromachined ultrasound transducer (PMUT) array with a top-down fabrication process. The fabrication uses a temporary carrier wafer from which the array device is released by deep reactive ion etching (DRIE). About 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!