A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The rib cage stabilizes the human thoracic spine: An in vitro study using stepwise reduction of rib cage structures. | LitMetric

The rib cage stabilizes the human thoracic spine: An in vitro study using stepwise reduction of rib cage structures.

PLoS One

Institute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University, Ulm, Germany.

Published: September 2017

The stabilizing effect of the rib cage on the human thoracic spine is still not sufficiently analyzed. For a better understanding of this effect as well as the calibration and validation of numerical models of the thoracic spine, experimental biomechanics data is required. This study aimed to determine (1) the stabilizing effect of the single rib cage structures on the human thoracic spine as well as the effect of the rib cage on (2) the flexibility of the single motion segments and (3) coupled motion behavior of the thoracic spine. Six human thoracic spine specimens including the entire rib cage were loaded quasi-statically with pure moments of ± 2 Nm in flexion/extension (FE), lateral bending (LB), and axial rotation (AR) using a custom-built spine tester. Motion analysis was performed using an optical motion tracking system during load application to determine range of motion (ROM) and neutral zone (NZ). Specimens were tested (1) in intact condition, (2) after removal of the intercostal muscles, (3) after median sternotomy, after removal of (4) the anterior rib cage up to the rib stumps, (5) the right sixth to eighth rib head, and (6) all rib heads. Significant (p < 0.05) increases of the ROM were found after dissecting the intercostal muscles (LB: + 22.4%, AR: + 22.6%), the anterior part of the rib cage (FE: + 21.1%, LB: + 10.9%, AR: + 72.5%), and all rib heads (AR: + 5.8%) relative to its previous condition. Compared to the intact condition, ROM and NZ increased significantly after removing the anterior part of the rib cage (FE: + 52.2%, + 45.6%; LB: + 42.0%, + 54.0%; AR: + 94.4%, + 187.8%). Median sternotomy (FE: + 11.9%, AR: + 21.9%) and partial costovertebral release (AR: + 11.7%) significantly increased the ROM relative to its previous condition. Removing the entire rib cage increased both monosegmental and coupled motion ROM, but did not alter the qualitative motion behavior. The rib cage has a strong effect on thoracic spine rigidity, especially in axial rotation by a factor of more than two, and should therefore be considered in clinical scenarios, in vitro, and in silico.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5453693PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0178733PLOS

Publication Analysis

Top Keywords

rib cage
44
thoracic spine
28
human thoracic
16
rib
15
anterior rib
12
cage
10
spine
8
cage structures
8
coupled motion
8
motion behavior
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!