Pinto, N, Salassi III, JW, Donlin, A, Schroeder, J, and Rozenek, R. Effects of a 6-week upper extremity low-volume, high-intensity interval training program on oxygen uptake, peak power output, and total exercise time. J Strength Cond Res 33(5): 1295-1304, 2019-The purpose of this study was to compare the effects of upper extremity (UE) high-intensity interval training (HIIT) to UE continuous training (CT) when training at a similar intensity. Twenty participants (mean age = 23 ± 3 years) were randomly assigned to either a HIIT (n = 10) or CT (n = 10) group. Participants completed a graded exercise test (GXT) utilizing arm cranking before and after 6 weeks (2 sessions per week) of UE training. During sessions, HIIT performed 10 repetitions of 60 seconds of work at 92.3 ± 1.0% of the arm HRpeak (%aHRpeak) and 60 seconds of passive recovery (%aHRpeak = 73.0 ± 4.0%) yielding an average training intensity of 82.6 ± 1.5 %aHRpeak. CT exercised for 20 minutes at an average intensity of 81.9 ± 2.2 %aHRpeak. After training, HIIT showed greater improvement in V[Combining Dot Above]O2peak compared with CT (Δ = 4.1 ml·min·kg, 95% confidence interval [CI]: 1.3-6.9 m·min·kg, p = 0.007). Total exercise time during the posttest GXT was also improved as a result of HIIT (Δ = 1.4 minutes, 95% CI: 0.4-2.3 minutes, p = 0.008). Both groups improved peak power output, but no difference was observed between them (Δ = 3.3 W, 95% CI: -3.3 to 9.9 W, p = 0.305). For a similar time investment, HIIT seemed to improve measures of cardiopulmonary capacity and exercise time to a greater extent than CT and may be a time-efficient alternative for those who incorporate UE aerobic activity into a training program.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0000000000002008DOI Listing

Publication Analysis

Top Keywords

exercise time
16
upper extremity
12
high-intensity interval
12
interval training
12
training program
12
peak power
12
power output
12
total exercise
12
training
9
effects 6-week
8

Similar Publications

Introduction: Abnormal cardiorespiratory symptoms and investigative findings in service personnel typically result in prolonged investigation and occupational restriction. This analysis aimed to assess the impact of the xford ilitary Cardiopulmonary xercise Testing linic (OMEC), which investigates such symptoms and findings, on occupational recommendations.

Methods: A service evaluation was conducted on all OMEC attendances over a 5-year period.

View Article and Find Full Text PDF

Objective: To analyze the effectiveness of three internal fixation methods, namely hollow screw combined with Kirschner wire tension band, hollow screw combined with anchor nail, and modified 1/3 tubular steel plate, in the treatment of avulsion fracture of tibial tubercle (AFTT) in adolescents.

Methods: Between January 2018 and September 2023, 19 adolescent AFTT patients who met the selection criteria were admitted. According to different internal fixation methods, patients were divided into group A (8 cases, hollow screw combined with Kirschner wire tension band), group B (6 cases, hollow screw combined with anchor nail), and group C (5 cases, modified 1/3 tubular steel plate).

View Article and Find Full Text PDF

Background: High-intensity physical activity has traditionally been discouraged in patients with hypertrophic cardiomyopathy due to concerns about triggering sudden cardiac death. However, current guidelines adopt a more liberal stance, and evidence on risk factors for exercise-related sudden cardiac death remains limited. This study investigated the clinical, morphological and genetic factors associated with high-intensity physical activity-related sudden cardiac death in hypertrophic cardiomyopathy.

View Article and Find Full Text PDF

Dysregulation of hypothalamic-pituitary-adrenal axis (HPA axis) and of the autonomic nervous system may link stress throughout the life course with poorer health. This study aims to investigate whether multiple adverse childhood experiences have a long-term impact on markers of these systems - cortisol secretion and heart rate variability - in adulthood. Data were from the Whitehall II cohort study.

View Article and Find Full Text PDF

Wearable heart rate variability analysis system based on ionic conductive hydrogels.

Talanta

January 2025

Academy of Medical Engineering and Translational Medicine, Medical School, Tianjin University, Tianjin, 300072, China; School of Exercise and Health, Tianjin University of Sport, Tianjin, 300211, China. Electronic address:

Developing a wearable device that can continuously and reliably detect and evaluate heart rate variability (HRV) parameters is critical for the diabetic population with cardiac autonomic neuropathy (CAN). In this work, we proposed a zwitterionic conducting hydrogel that enabled a reliable and comfortable wearable device for the evaluation and detection of the autonomic nervous system (ANS). The hydrogel can achieve a strain of 2003 %, an electrical conductivity of 190 mS/m, and is capable of adhering to a variety of materials, including wood, plastic, and glass.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!