Aims: Femoral stems with exchangeable (modular) necks were introduced to offer surgeons an increased choice when determining the version, offset and length of the femoral neck during total hip arthroplasty (THA). It was hoped that this would improve outcomes and reduce complications, particularly dislocation. In 2010, the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) first reported an increased rate of revision after primary THA using femoral stems with an exchangeable neck. The aim of this study was to provide a more comprehensive up-to-date analysis of primary THA using femoral stems with exchangeable and fixed necks.
Materials And Methods: The data included all primary THA procedures performed for osteoarthritis (OA), reported to the AOANJRR between 01 September 1999 and 31 December 2014. There were 9289 femoral stems with an exchangeable neck and 253 165 femoral stems with a fixed neck. The characteristics of the patients and prostheses including the bearing surface and stem/neck metal combinations were examined using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship.
Results: It was found that prostheses with an exchangeable neck had a higher rate of revision and this was evident regardless of the bearing surface or the size of the femoral head. Exchangeable neck prostheses with a titanium stem and a cobalt-chromium neck had a significantly higher rate of revision compared with titanium stem/titanium neck combinations (HR 1.83, 95% confidence interval 1.49 to 2.23, p < 0.001). Revisions were higher for these combinations compared with femoral stems with a fixed neck.
Conclusion: There appears to be little evidence to support the continued use of prostheses with an exchangeable neck in primary THA undertaken for OA. Cite this article: 2017;99-B:766-73.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1302/0301-620X.99B6.38020 | DOI Listing |
Cureus
January 2025
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, JPN.
Introduction Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years.
View Article and Find Full Text PDFCureus
December 2024
Orthopedic Surgery, Sengkang General Hospital, Singapore, SGP.
Background: Femoral condyle insufficiency fractures following total knee arthroplasty (FCIF-TKA) are rare but significant complications. These fractures, characterized by atraumatic bone insufficiency near the femoral component, present unique challenges in postoperative care, often necessitating femoral component revision.
Methods: This study retrospectively reviewed 835 primary total knee arthroplasties performed by a single surgeon, identifying six cases of FCIF-TKA.
J Am Acad Orthop Surg
January 2025
From the Hawaii Permanente Medical Group, Kaiser Permanente, Honolulu, HI (Okike), the Department of Surgical Outcomes and Analysis, Kaiser Permanente, San Diego, CA (Prentice, Paxton, and Fasig), the San Francisco Orthopaedic Residency Program, San Francisco, CA (Shah), the Permanente Medical Group, Oakland, CA (Grimsrud), and the Washington Permanente Medical Group P.C, Seattle, WA (Chen).
Background: Cemented fixation is recommended in the hemiarthroplasty treatment of geriatric femoral neck fractures. Certain cemented stems have similarly designed "low-demand" counterparts, but it is unclear whether they yield comparable clinical outcomes. The purpose of this study was to evaluate the revision risk associated with two low-demand stems, Summit Basic (DePuy Synthes) and Versys LD/Fx (Zimmer Biomet), in comparison to their standard counterparts, Summit (DePuy Synthes) and Versys Advocate (Zimmer Biomet).
View Article and Find Full Text PDFIowa Orthop J
January 2025
Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
Background: Cementless stems are commonly used in hemiarthroplasty (HA) for femoral neck fractures. Recent studies have reported increased risk of periprosthetic fracture with cementless stems compared to cemented HA. In elective total hip arthroplasty (THA), lower proximal canal fill ratios (CFR) of cementless stems have been associated with worse outcomes.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Orthopaedic Surgery, The First Affiliated Hospital of Naval Medical University: Changhai Hospital, Shanghai, China.
Short-stem total hip arthroplasty (SHA) has become popular because it preserves femoral bone stock and enables the use of short femoral stems in revision total hip arthroplasty (THA). However, no study has evaluated whether a short stem in revision THA, replacing a standard stem, can provide adequate primary stability to facilitate osseous integration. In this biomechanical study, a metaphyseal anchoring SHA (Tri-Lock BPS) stem and a standard THA (Corail) stem were implanted into ten composite femurs and loaded dynamically from 300 to 1700 N with 1 Hz.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!