  • The study introduces the FLA-500-SD, an ultraminiature and wearable electromyogram (EMG) system designed for recording muscle activity, particularly from the masseter muscle.
  • The device is compact, measuring just 37.0×23.5×8.6mm, and can be self-operated by patients in their daily lives, with data stored on a micro SD card for later analysis.
  • This innovative system has the potential for various clinical applications, like assessing bruxism and monitoring chewing patterns, marking it as the smallest and lightest data-logger-type electromyograph with advanced capabilities.

Article Abstract

Purpose: We describe the characteristics of a new data-logger-type ultraminiature electromyogram (EMG) system (FLA-500-SD) and methods used for recording and we show its potential in clinical applications by presenting an example of a clinical case.

Method: FLA contains electrodes, an amplifier, 12-bit analog-to-digital (A/D) converter at a sampling frequency of 1kHz, 16-bit CPU, a 3.7-V coin-shaped lithium battery, and a micro SD card. The size of FLA is 37.0×23.5×8.6mm, and its weight is 6g (9g with a battery inserted). The device is wearable and patients can attach the device and operate it by themselves in daily life. Data recorded in the micro SD card are transferred to a personal computer and analyzed. Although the device is ultraminiature and wearable, it has the capacity for recording a precise and clear masseteric surface electromyogram that is not inferior to that recorded by conventional stationary-type EMG recording systems.

Conclusions: To our knowledge, the device is the smallest and lightest device with capacity for the longest consecutive measuring time as a data-logger-type electromyograph with built-in electrodes and memory. The device is useful for analyses of masseteric activity during the whole day. In the future, it is expected that applications of the device will expanded to observation, evaluation and diagnosis of normal or abnormal gnathic functions, e.g., assessment of sleep and awake bruxism and observation of the chewing state in daily life.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpor.2017.04.001DOI Listing

Publication Analysis

Top Keywords

ultraminiature wearable
8
analyses masseteric
8
masseteric activity
8
activity day
8
micro card
8
daily life
8
device
7
newly developed
4
developed ultraminiature
4
wearable electromyogram
4

Similar Publications

Purpose: This study aimed to elucidate the relationship between diurnal masseter muscle activity and awareness of diurnal awake bruxism (d-AB) by conducting a comparative analysis of electromyographic (EMG) data from individuals with and without awareness of diurnal awake bruxism (d-AB), utilizing EMG data gathered from multiple subjects.

Methods: Unilateral masseter electromyography (EMG) recordings were performed during the daytime using an ultraminiature wearable EMG device. A total of 119 participants (59 with awareness of diurnal tooth clenching [d-TC] and 60 without awareness of d-TC) were included.

View Article and Find Full Text PDF

Introduction: In the principles of the organization of armed struggle of the defense forces of most developed countries of the world, considerable attention is paid to the evaluation of combat readiness of the military personnel. This procedure is conditioned by such interconnected goals of the armed struggle as the maximum realization of the combat potential and the minimization of personnel losses. The purpose of the work is to determine the physiological cost of the activities of the soldiers of the Defense Forces of Ukraine with the help of miniature electrocardiographic hardware and software complexes.

View Article and Find Full Text PDF

Rodent electroencephalography (EEG) in preclinical research is frequently conducted in behaving animals. However, the difficulty inherent in identifying EEG epochs associated with a particular behavior or cue is a significant obstacle to more efficient analysis. In this paper we highlight a new solution, using infrared event stamping to accurately synchronize EEG, recorded from superficial sites above the hippocampus and prefrontal cortex, with video motion tracking data in a transgenic Alzheimer's disease (AD) mouse model.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to clarify the validity of assessment of sleep bruxism (SB) by using single-channel electromyogram (EMG) and a cut-off value with optimum sensitivity and specificity.

Methods: The subjects were twenty volunteers with clinical diagnosis of SB. Assessment by masseteric EMG data only by using a wearable EMG was compared with reference standard assessment by masseteric EMG data using polysomnography with audio-visual recording (PSG-AV).

View Article and Find Full Text PDF
Article Synopsis
  • The study introduces the FLA-500-SD, an ultraminiature and wearable electromyogram (EMG) system designed for recording muscle activity, particularly from the masseter muscle.
  • The device is compact, measuring just 37.0×23.5×8.6mm, and can be self-operated by patients in their daily lives, with data stored on a micro SD card for later analysis.
  • This innovative system has the potential for various clinical applications, like assessing bruxism and monitoring chewing patterns, marking it as the smallest and lightest data-logger-type electromyograph with advanced capabilities.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!