Functional monitoring of peripheral nerves from electrical impedance measurements.

J Physiol Paris

Univ Grenoble Alpes, Grenoble Institut des Neurosciences, GIN, F-38000 Grenoble, France; Inserm, U1216, F-38000 Grenoble, France. Electronic address:

Published: November 2016

Medical electrical stimulators adapted to peripheral nerves use multicontact cuff electrodes (MCC) to provide selective neural interfaces. However, neuroprostheses are currently limited by their inability to locate the regions of interest to focus. Intended until now either for stimulation or recording, MCC can also be used as a means of transduction to characterize the nerve by impedancemetry. In this study, we investigate the feasibility of using electrical impedance (EI) measurements as an in vivo functional nerve monitoring technique. The monitoring paradigm includes the synchronized recording of both the evoked endogenous activity as compound action potentials (CAP) and the superimposed sine signal from the EI probe. Measurements were conducted on the sciatic nerve of rodents, chosen for its branchings towards the peroneal and tibial nerves, with both mono- and multi-contact per section electrodes. During stimulation phases, recordings showed CAP with consistent fiber conduction velocities. During coupled phases of both stimulation and sine perturbation, impedance variations were extracted using the mono-contact electrode type for certain frequencies, e.g. 2.941kHz, and were temporally coherent with the previous recorded CAP. Using a MCC, localized evoked CAP were also recorded but the signal to noise ratio (SNR) was too low to distinguish the expected associated impedance variation and deduce an image of impedance spatial changes within the nerve. The conducted in vivo measurements allowed to distinguish both evoked CAP and associated impedance variations with a strong temporal correlation. This indicates the feasibility of functional EI monitoring, aiming at detecting the impedance variations in relation to neural activity. Further work is needed to improve the in vivo system, namely in terms of SNR, and to integrate new multicontact devices in order to move towards EI tomography with the detection of spatially-localized impedance variations. Eventually, regions that are interesting to be targeted by stimulation could be identified through these means.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jphysparis.2017.05.003DOI Listing

Publication Analysis

Top Keywords

impedance variations
16
functional monitoring
8
peripheral nerves
8
impedance
8
electrical impedance
8
impedance measurements
8
evoked cap
8
associated impedance
8
cap
5
monitoring peripheral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!