A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assistive Techniques for Proximal Anastomosis in Minimally Invasive Coronary Artery Bypass Grafting. | LitMetric

Assistive Techniques for Proximal Anastomosis in Minimally Invasive Coronary Artery Bypass Grafting.

Innovations (Phila)

From the *Department of Cardiac Surgery, Wuhan Asia Heart Hospital, Wuhan, China; and †Division of Cardiovascular Surgery, Yamato Seiwa Hospital, Yamato City, Japan.

Published: March 2018

We introduce assistive techniques for proximal anastomosis in off-pump minimally invasive coronary artery bypass grafting (MICS CABG) to overcome difficult access to the ascending aorta in MICS CABG. An 8-cm left thoracotomy is made in the fifth intercostal space. ThoraTrak retractor (Medtronic Inc, Minneapolis, MN USA) is used to open the thoracotomy and is pulled to the cephalad and rightward direction toward to the ascending aorta. The pericardium is opened from the ascending aorta to the left ventricular apex and to the inferior vena cava. Two retraction sutures on the pericardial edge are used to laterally displace the heart. After dissecting between the ascending aorta and main pulmonary artery, the Octopus tissue stabilizer (Medtronic Inc, Minneapolis, MN USA), of which the suction tip is bent 60 degrees, is used to retract the pulmonary artery caudally. A flexible side-biting clamp (Vitalitec Inc.) is placed on the ascending aorta, and proximal anastomoses are handsewn on the ascending aorta. A total of 31 proximal anastomoses were completed with this technique between November 2013 and June 2015. All proximal anastomosis was completed without any difficulty. In MICS CABG, the technical challenges in proximal anastomosis due to difficult access to the aorta can be overcome safely by using this technique.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IMI.0000000000000366DOI Listing

Publication Analysis

Top Keywords

ascending aorta
24
proximal anastomosis
16
mics cabg
12
assistive techniques
8
techniques proximal
8
minimally invasive
8
invasive coronary
8
coronary artery
8
artery bypass
8
bypass grafting
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!