Background And Aims: The aim of this study was to assess the radiopacity of two bioceramic-based root canal sealers, the conventional TotalFill BC sealer (FKG Dentaire Switzerland) and a new experimental filling material developed in collaboration with 'Raluca Ripan' Institute for Research in Chemistry, Cluj-Napoca.
Methods: Five disc samples were prepared using both materials (10 mm diameter × 1 mm thickness), being subjected to digital radiography together with aluminum step wedges (1 to 12 mm in thickness), in accordance with ISO 6876: 2012. Radiopacity was determined by the computer analysis of the images obtained. Four different areas were selected for each sample, corresponding to a disk-sample quadrant. Statistical analysis was performed using ANOVA.
Results: Both materials showed a radiopacity that was 3 mm greater than the equivalent thickness of aluminum. Total Fill BC showed greater radiopacity than the experimental material, but the differences were not statistically significant.
Conclusions: Both materials comply with ISO 6876: 2012 recommendations on minimum radiopacity.