The simultaneous use of 2 external defibrillators to administer either dual or sequential cardioversion or defibrillation for refractory cardiac arrhythmias is increasing in both the out-of-hospital and inhospital settings. Using 2 defibrillators to administer higher energy levels than can be achieved with a single defibrillator is considered off-label and is currently not part of published advanced cardiac life support guidelines. We report the first case in which the use of dual-dose cardioversion was associated with external defibrillator damage. Because defibrillator damage, especially if undetected, jeopardizes patient safety and off-label medical product use may void the manufacturer's warranty, this case should urge users to proceed with caution when contemplating this technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.annemergmed.2017.04.005 | DOI Listing |
JMIR Form Res
January 2025
Department of Anesthesiology and Perioperative Medicine, The First Affiliated Hospital of Nanjing Medical University, No. 300 Guangzhou Road, Nanjing, 210029, China, 86 2568303569.
Background: Ventricular fibrillation (VF) is a vicious arrhythmia usually generated after removal of the aortic cross-clamp (ACC) in patients undergoing open-heart surgery, which could damage cardiomyocytes, especially in patients with left ventricular hypertrophy (LVH). Amiodarone has the prominent properties of converting VF and restoring sinus rhythm. However, few studies concentrated on the effect of amiodarone before ACC release on reducing VF in patients with LVH.
View Article and Find Full Text PDFStrahlenther Onkol
January 2025
TUM School of Medicine and Health, Department of Radiation Oncology, Technische Universität München (TUM), Klinikum rechts der Isar, Munich, Germany.
Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Electrophysiology and Cardiac Pacing Unit, San Giuliano Hospital, Giugliano in Campania, Italy.
We present the case of a 64-year-old man who, during the implantation of an active-fixation leadless pacemaker (LP, Aveir VR, Abbott, USA), underwent several external defibrillation shocks up to 240 Joules, due to symptomatic sustained supraventricular tachycardia at 160 bpm. The shocks, delivered both before and after the screwing of the device in the low interventricular septum, did not cause any technical damage to the device, and no complications were observed. The device was then deployed successfully.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, location AMC, The Netherlands.
The extravascular implantable cardioverter-defibrillator (EV-ICD) was developed to overcome complications associated with transvenous leads while being able to deliver anti-tachycardia pacing (ATP). The lead is implanted in the substernal space, which makes extraction a cautious procedure. We present a case of a 51-year-old women with a successful EV-ICD extraction after a lead dwell time of 4 years, which is the longest reported.
View Article and Find Full Text PDFZhonghua Wei Zhong Bing Ji Jiu Yi Xue
October 2024
Department of Vascular Surgery, Gansu Provincial People's Hospital, Lanzhou 730000, Gansu, China. Corresponding author: Zhang Zhigang, Email:
Objective: To comprehensively search the relevant literature on prone position-cardiopulmonary resuscitation (PP-CPR) in adults at home and abroad, analyze the content, summarize the evidence, and provide reference for clinical health care professionals.
Methods: Systematic search of CNKI, China Biomedical Literature Service System (SinoMed), Wanfang Data, VIP database, PubMed, Embase, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Cochran Library, Web of Science, Scopus literature database and other Chinese and English databases was conducted. The search period was from inception to June 15 in 2024.