Expanded polytetrafluoroethylene (ePTFE), also known as Gore-Tex, is widely used as an implantable biomaterial in biomedical applications because of its favorable mechanical properties and biochemical inertness. However, infection and inflammation are two major complications with ePTFE implantations, because pathogenic bacteria can inhabit the microsized pores, without clearance by host immune cells, and the limited biocompatibility can induce foreign body reactions. To minimize these complications, we covalently grafted a biomembrane-mimic polymer, poly(2-methacryloyloxylethyl phosphorylcholine) (PMPC), by partial defluorination followed by UV-induced polymerization with cross-linkers on the ePTFE surface. PMPC grafting greatly reduced serum protein adsorption as well as fibroblast adhesion on the ePTFE surface. Moreover, the PMPC-grafted ePTFE surface exhibited a dramatic inhibition of the adhesion and growth of Staphylococcus aureus, a typical pathogenic bacterium in ePTFE implants, in the porous network. On the basis of an analysis of immune cells and inflammation-related factors, i.e., transforming growth factor-β (TGF-β) and myeloperoxidase (MPO), we confirmed that inflammation was efficiently alleviated in tissues around PMPC-grafted ePTFE plates implanted in the backs of rats. Covalent PMPC may be an effective strategy for promoting anti-inflammatory and antibacterial functions in ePTFE implants and to reduce side effects in biomedical applications of ePTFE.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.7b02696DOI Listing

Publication Analysis

Top Keywords

eptfe surface
12
eptfe
9
anti-inflammatory antibacterial
8
biomembrane-mimic polymer
8
biomedical applications
8
immune cells
8
pmpc-grafted eptfe
8
eptfe implants
8
antibacterial effects
4
effects covalently
4

Similar Publications

Artificial vascular grafts, as blood vessel substitutes, are a prime challenge in tissue engineering and biomaterial research. An ideal artificial graft must have physiological and mechanical properties similar to those of a natural blood vessel, and hemocompatibility on its surface. We designed and fabricated artificial grafts by applying 3D printing and templated technology, which is endowed with morphologically patient-specific vascular reconstruction.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to characterize the morphological and immunological aspects of biointegration at the optic-cornea joint of a second-generation synthetic corneal device.

Methods: The initial prototype, single-piece optic-skirt configuration, is constructed from compact and flexible perfluoroalkoxy alkane with porous expanded polytetrafluoroethylene (ePTFE) overlying the skirt to allow skirt-cornea biointegration. The second-generation version was modified to add ePTFE around the optic wall to allow optic-cornea biointegration.

View Article and Find Full Text PDF

A comparative study between condensed polytetrafluoroethylene hernia mesh versus other composite meshes in Endo-laparoscopic ventral hernia repair.

Asian J Surg

November 2024

Division of Minimally Invasive Surgery, Department of Surgery, National University Hospital, Singapore; Department of Surgery, National University of Singapore, Singapore.

Introduction: Laparoscopic ventral hernia mesh repair (LVHR) is gaining popularity possibly due to reduced complications, reduced hospital stay, early return to work and better cosmesis. In intra-peritoneal onlay method (IPOM) a dual layer composite mesh with an absorbable barrier on the visceral surface is used for minimising bowel adhesions. Three most popular prosthetic mesh scaffolds are polypropylene (PP), polyester and expanded polytetrafluoroethylene (ePTFE).

View Article and Find Full Text PDF

PTFE Stent Membrane Based on the Electrospinning Technique and Its Potential for Replacing ePTFE.

ACS Appl Bio Mater

December 2024

National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, No. 199 Ren'ai Road, Industrial Park, Suzhou 215123, PR China.

Expanded poly(tetrafluoroethylene) (ePTFE), obtained by the paste extrusion-stretching method, is a commonly used stent membrane material for the treatment of arterial stenosis or aneurysm in clinical practice. However, the structure of ePTFE is nonfibrous, which is not friendly to cells, and the equipment consumes a lot of energy and often requires the use of flammable and toxic lubricants. In this study, electrospinning was used to prepare PTFE vascular stent membranes, following plasma treatment, dopamine, and heparin grafting to obtain an anticoagulant surface.

View Article and Find Full Text PDF

Expanded polytetrafluoroethylene (ePTFE) failed to achieve clinical application in the field of small-diameter blood vessels due to its lack of elasticity in the circumferential direction and high stiffness. Excellent multidirectional elasticity and dynamic compliance matching with natural blood vessels are important means to solve the problem of acute thrombosis and poor long-term patency. Herein, novel PTFE spinning blood vessels were prepared by the PTFE emulsion electrospinning process, which not only presented good bidirectional elasticity but also promoted the adhesion and proliferation of endothelial cells and induced the contractile expression of SMCs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!