Background: External ventricular drain (EVD) placement is a frequently performed neurosurgical procedure. Inaccuracies in drain positioning and the need for multiple passes using the classic freehand insertion technique is well reported in the literature, especially in the traumatic brain injury (TBI) population. The purpose of this study was to evaluate if electromagnetic neuronavigation guidance for EVD insertion improves placement accuracy and minimizes the number of passes in severe TBI patients.
Methods: Navigation was applied prospectively for all new severe TBI patients who required ventricular catheter placement over a period of 1 year, and compared with a retrospective cohort of severe TBI patients who had EVD inserted freehand in the preceding year. The placement accuracy was evaluated using the Kakarla grading system; the number of passes was also compared.
Results: Fifty-four cases were recruited: 35 (64.8%) had their EVD placed using the freehand technique and 19 (35.2%) using navigation guidance. In the navigation group, the placement accuracy was: 94.7% (18/19) grade 1, 5.3% (1/19) grade 2, and none at grade 3. In comparison, freehand placement was associated with misplacement (grades 2 and 3) in 42.9% of the cases (p value = 0.009). The number of passes was significantly lower in the navigation group (mean of 1.16 ± 0.38), compared with the freehand group (mean of 1.63 ± 0.88) (p value = 0.018).
Conclusions: Using the navigation to guide EVD placement was associated with a significantly better accuracy and a lower number of passes in severe TBI patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00701-017-3201-5 | DOI Listing |
Oral Maxillofac Surg Clin North Am
January 2025
Full Arch Solutions +, 6848 Magnolia Avenue, #100, Riverside, CA, USA.
This article highlights the critical role of digital technologies, particularly photogrammetry, in full-arch dental implant practices. By replacing traditional analog methods, digital tools enhance the precision of implant placement and prosthetic design, leading to better functional and esthetic outcomes. The seamless integration of photogrammetry with a computer-aided design /computer-aided manufacturing system not only streamlines the workflow but also improves patient satisfaction by reducing treatment times and increasing comfort.
View Article and Find Full Text PDFEur Spine J
January 2025
In Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Purpose: The objective of this systematic review is to present a comprehensive summary of existing research on the use of 3D printing in spinal surgery.
Methods: The researchers conducted a thorough search of four digital databases (PubMed, Web of Science, Scopus, and Embase) to identify relevant studies published between January 1999 and December 2022. The review focused on various aspects, including the types of objects printed, clinical applications, clinical outcomes, time and cost considerations, 3D printing materials, location of 3D printing, and technologies utilized.
Anesth Analg
November 2024
From the Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Boston, Massachusetts.
Background: Hypoxemia occurs with relative frequency during one-lung ventilation (OLV) despite advances in airway management. Lung perfusion scans are thought to be one of the most accurate methods to predict hypoxemia during OLV, but their complexity and costs are well-known limitations. There is a lack of preoperative stratification models to estimate the risk of intraoperative hypoxemia among patients undergoing thoracic surgery.
View Article and Find Full Text PDFAnn Med
December 2025
Catholic Institute for Applied Anatomy, Department of Anatomy, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Introduction: The clinical feasibility and applicability of surface landmarks for Baxter nerve entrapment to proximal and distal sites is unclear. This study provides anatomical guidelines for optimal transducer placement using two specific landmarks, the most inferior tip of the medial malleolus (A) and the most protruding posterior tip of the calcaneus (B), to enhance the diagnostic and therapeutic injection efficacy for proximal and distal entrapment sites.
Materials And Methods: Eighty-six feet from 45 fresh cadavers (25 male and 20 female) were dissected to determine Baxter's nerve (BN) localization.
Medicina (Kaunas)
December 2024
Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea.
: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation remains crucial for assessing screw placement and related potential complications.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!