Purpose: To compare the outcome of site preparation for zygomatic oncology implants using conventional preparation with rotary drills or piezoelectric surgery with dedicated inserts for placing two zygomatic implants per zygoma according to a split-mouth design.
Materials And Methods: Twenty edentulous patients with severely atrophic maxillas not having sufficient bone volume for placing dental implants and less than 4 mm of bone height subantrally had their hemi-maxillas randomised according to a split-mouth design into implant site preparation with conventional rotational drills or piezoelectric surgery. Two zygomatic oncology implants (unthreaded coronal portion) were placed in each hemi-maxilla. Implants that achieved an insertion torque superior to 40 Ncm were immediately loaded with screw-retained metal reinforced acrylic provisional prostheses. Outcome measures were: prosthesis and implant failures, any complications, time to place the implants, presence of post-operative haematoma, and patient's preference by independent assessors. All patients were followed up to 1 year after loading.
Results: In two patients drills had also to be used at the piezoelectric surgery side to enable implant sites to be prepared. One implant for the conventional drill group did not achieve an insertion torque superior to 40 Ncm since it fractured the zygoma. No patients dropped out and two distal oncology implants failed in the same patient (one per group), who was not prosthetically rehabilitated. Six complications occurred at drilled sites and three at piezoelectric surgery sites (two patients had bilateral complications), the difference being not statistically significant (P (McNemar's test) = 0.375; odds ratio = 4.00; 95% CI of odds ratio: 0.45 to 35.79). Implant placement with convention drills took on average 14.35 ± 1.76 min and with piezoelectric surgery 23.50 ± 2.26 min, implant placement time being significantly shorter with conventional drilling (difference = 9.15 ± 1.69 min; 95%CI: 8.36 to 9.94 min; P < 0.001). Post-operative haematomas were more frequent at drilled sites (P = 0.001), and 16 patients found both techniques equally acceptable, while four preferred piezoelectric surgery (P = 0.125).
Conclusions: Both drilling techniques achieved similar clinical results, but conventional drilling required 9 min less and could be used in all instances, although it was more aggressive. These results may be system-dependent, therefore they cannot be generalised to other zygomatic systems with confidence. Conflict-of-interest statement: This study was partially supported by Southern Implants (Irene, South Africa), the manufacturer of the zygomatic implants and the conventional drills evaluated in this study. However, data property belonged to the authors and by no means did the manufacturer interfere with the conduct of the trial or the publication of its results. Drs Felice and Pistilli developed the piezoelectric surgery zygomatic insert used in the present study.
Download full-text PDF |
Source |
---|
Medicina (Kaunas)
December 2024
Department of Life, Health and Environmental Sciences, School of Dentistry, University of L'Aquila, 67100 L'Aquila, Italy.
: Third molar (wisdom tooth) extraction is one of the most common surgical procedures in oral and maxillofacial surgery. Traditional rotary instruments and burs have long been the standard tools for this procedure. However, recent advancements in surgical techniques, such as piezoelectric surgery, have gained popularity due to their purported advantages in terms of precision, safety, and postoperative outcomes.
View Article and Find Full Text PDFInt J Biol Macromol
December 2024
Department of Cosmetic and Plastic Surgery, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China. Electronic address:
Polyhydroxyalkanoates (PHAs) are a group of polymers with a variety of monomers, which are extracted from microorganisms and plants. Due to its good biocompatibility, biodegradability, tunable mechanical property and piezoelectricity, PHAs have been widely used in biomedical fields, such as bone, cartilage, nerve, vascular and skin tissue engineering. This review focuses on the in vivo synthesis, metabolism and biological functions of PHA, and the applications of PHAs in the field of tissue engineering and commercial were also summarized and discussed.
View Article and Find Full Text PDFBioact Mater
March 2025
Department of Oral, Plastic and Aesthetic Surgery, Hospital of Stomatology, Jilin University, Changchun, 130021, China.
Clinically, infectious bone defects represent a significant threat, leading to osteonecrosis, severely compromising patient prognosis, and prolonging hospital stays. Thus, there is an urgent need to develop a bone graft substitute that combines broad-spectrum antibacterial efficacy and bone-inductive properties, providing an effective treatment option for infectious bone defects. In this study, the precision of digital light processing (DLP) 3D printing technology was utilized to construct a scaffold, incorporating zinc oxide nanoparticles (ZnO-NPs) modified barium titanate (BT) with hydroxyapatite (HA), resulting in a piezoelectric ceramic scaffold designed for the repair of infected bone defects.
View Article and Find Full Text PDFInt J Implant Dent
December 2024
Department of Oral and Maxillofacial Surgery, University Medical Center, Johannes Gutenberg University, Augustusplatz 2, 55131, Mainz, Germany.
Purpose: To evaluate whether there are clinical benefits by preparing dental implant sites using piezosurgery instead of conventional rotary drills in healed bone crests and if initial crestal soft tissue thickness could have an impact on marginal bone loss.
Methods: Twenty-five partially edentulous patients requiring two single implants in molar/premolar areas had each site randomly allocated to either piezosurgery or to conventional rotary drill preparation according to a split-mouth design. Definitive screw-retained metal-ceramic crowns were delivered after 6 months.
Adv Mater
December 2024
Department of Foot and Ankle Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.
Electrical stimulation enhances cellular activity, promoting tissue regeneration and repair. However, specific cells and maintaining a stable energy supply are challenges for precise cell electrical stimulation therapy. Here, force-electric conversion hydrogel microspheres (Piezo@CR MPs) is devloped to induce specific stem cell aggregation and promote chondrogenic differentiation through localized electrical stimulation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!