The number of older workers in the workforce is increasing substantially, and advanced age is associated with factors that could influence musculoskeletal injury risk and work capacity. This study's goals were to test whether psychophysical estimates of maximum acceptable weight of lift (lift) differed between younger and older workers, and to examine potential explanatory factors. Twenty-four female workers (half 50 + years; half 20-32 years) self-adjusted a box's mass to their perceived lift during four lifting tasks. Older workers' lift values were significantly lower (by approximately 24%) than their younger counterparts. There were no age-related differences in resting heart rate, or peak joint angles and final heart rate during the lifting trials. However, the older group demonstrated lower grip strength (by 24%), and lower heart rate reserve during the trials (by 18%). These results question whether current maximum acceptable lifting weights based on psychophysical information are appropriately protective for female workers greater than 50 years of age. Practitioner Summary: This psychophysical study demonstrated that older female workers (aged 50-63 years) selected maximum acceptable lift masses that were (on average) 24% lower than younger workers (aged 20-32 years), which corresponded with lower grip strength and heart rate reserve. Current maximum acceptable lifting weights based on psychophysical information may not protect female workers greater than 50 years of age.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/00140139.2017.1335883 | DOI Listing |
J Environ Radioact
December 2024
Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, 518063, China. Electronic address:
Gamma-ray coded-aperture imaging technology has important applications in the fields of nuclear security, isolated source detection, and the decommissioning of nuclear facilities. However, artifacts can reduce the quality of reconstructed images and affect the identification of the intensity and location of radioactive sources. In this paper, a gamma-ray coded-aperture imaging method based on primitive and reversed coded functions (PRCF) was proposed to reduce imaging artifacts.
View Article and Find Full Text PDFToxins (Basel)
November 2024
Toxins, Organic Contaminants and Additives, Physical and Chemical Health Risks, Sciensano, Leuvensesteenweg 17, 3080 Tervuren, Belgium.
Hydroxyanthracene derivatives (HADs) are plant substances produced by a variety of plant species, including different , , and species and These plants are often used in food supplements to improve bowel function. However, recently, the European Commission prohibited a number of HADs due to toxicological concerns. These HADs included aloin (aloin A and aloin B), aloe-emodin, emodin, and danthron.
View Article and Find Full Text PDFJ Funct Morphol Kinesiol
December 2024
Escuela de Ciencias de la Actividad Física, El Deporte y la Salud, Facultad de Ciencias Médicas, Universidad de Santiago de Chile, Santiago 8370003, Chile.
Assessing the reliability of measurement instruments and equipment is essential to ensure the accurate tracking of athletes over extended periods, minimizing the measurement errors caused by chance or other factors. However, a less common but equally important analysis is the verification of inter-measurement agreement, which complements the reliability results. To evaluate the intra- and inter-test reliability of an isometric hip adduction strength and asymmetries test in professional soccer players.
View Article and Find Full Text PDFAudiol Res
December 2024
Department of Clinical Sciences and Community Health, University of Milan, 20122 Milan, Italy.
Introduction: Acceptable Noise Level (ANL) is defined as the most comfortable level (MCL) intensity for speech and is calculated by subtracting the maximum noise tolerable by an individual. The ANL test has been used over time to predict hearing aid use and the impact of digital noise reduction. This study analyzes this impact by using different masker babble spectra when performing the ANL test in both hearing-impaired and healthy subjects in three different languages (Dutch, French, and Italian).
View Article and Find Full Text PDFJOR Spine
December 2024
TÜV Süd Product Service GmbH Hamburg Germany.
Background: Spinal implant failure is associated with prolonged patient suffering, high costs for the medical device industry, and a high economic burden for the health care system. Pre-clinical mechanical testing has great potential to reduce the risk of such failure. However, there are no binding regulations for planning and interpretation of mechanical testing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!