Purpose: This study aims to assess the feasibility and the effectiveness of a fetoscopic myelomeningocele (MMC) coverage using a sealed inert patch through a two-port access, in the sheep model.

Methods: Forty-four fetuses underwent surgical creation of a MMC defect at day 75 and were divided into four groups according to the MMC repair technique, performed at day 90. Group 1 remained untreated. Group 2 had an open surgery using suture of the defect. Groups 3 and 4 underwent defect coverage using a Gore®-polytetrafluoroethylene patch secured with surgical adhesive (Bioglue®), with an open approach (group 3) and a fetoscopic one (group 4). Lambs were killed at term, and histological examinations were performed.

Results: Fetoscopic patch coverage was achieved in all the lambs of group 4. All the fetuses of group 2 had a complete closure of the defect whereas only 38% in group 3 and 14% in group 4. Fetal loss rate seems to be lower in group 4 than in groups 2 and 3.

Conclusion: Fetoscopic coverage of MMC defect can be performed using a sealed patch through a two-port access, but the patch and glue correction may not be the ideal technique to repair fetal MMC.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00381-017-3461-7DOI Listing

Publication Analysis

Top Keywords

two-port access
12
group
9
fetoscopic patch
8
patch coverage
8
patch two-port
8
mmc defect
8
fetoscopic
5
coverage
5
mmc
5
patch
5

Similar Publications

Objective: This work aims to describe the evolution of the video-assisted Thoracoscopic Surgery (VATS) approach from a multiportal access to a biportal access for thoracic herniated disc surgery. Thoracic disc herniation remains a challenging pathology for spine surgeons. VATS of the thoracic spine was described in the 90s and represented an important technical leap by including minimally invasive options for thoracic pathology.

View Article and Find Full Text PDF

Periareolar approach in video-assisted thoracoscopic surgery for right middle lobectomy: a novel technique.

Surg Endosc

September 2024

Department of Thoracic Surgery, Renmin Hospital of Wuhan University, 238 Jiefang Road, Wuhan, 430060, People's Republic of China.

Background: Uniportal thoracoscopic right middle lobectomy (RML) poses greater technical challenges than other lobectomies. Although two-port thoracoscopy offers convenience, it results in heightened surgical trauma and scarring. The periareolar incision is rarely used in lobectomy while known for its cosmetic advantages.

View Article and Find Full Text PDF

Although the phenomenon of memory formation and recall associated with the use of psychotropic drugs has been extensively studied, mechanisms underlying memories for natural reward have not been clarified. Herein, we test the hypothesis that glutamatergic receptors in the dentate gyrus play a role in memories associated with sucrose. We used pellet self-administration protocol to generate memories in two-port nose-poke discrimination task using male Wistar rats.

View Article and Find Full Text PDF

Video assisted retroperitoneal debridement for infected pancreatic necrosis: A two port approach for difficult access.

Int J Surg Case Rep

June 2024

Estudiante de posgrado Cirugía General, Pontificia Universidad Javeriana, Facultad de Medicina, Bogotá, Colombia; Department of Surgery, Hospital Universitario Fundación Santa Fe de Bogotá, Colombia.

Introduction And Importance: The incidence of acute pancreatitis varies globally, and its rates are increasing. Timely intervention in cases of infected necrosis is crucial to effective management. The landscape of acute pancreatitis management has undergone transformation through adopting a "step-up" strategy, accentuating the shift towards minimally invasive techniques.

View Article and Find Full Text PDF

Mutual Coupling Reduction in Compact MIMO Antenna Operating on 28 GHz by Using Novel Decoupling Structure.

Micromachines (Basel)

November 2023

Department of Electrical Engineering, College of Engineering, Qassim University, Unaizah 56452, Saudi Arabia.

This article presents an antenna with compact and simple geometry and a low profile. Roger RT6002, with a 10 mm × 10 mm dimension, is utilized to engineer this work, offering a wideband and high gain. The antenna structure contains a patch of circular-shaped stubs and a circular stub and slot.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!