A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Correlation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataracts. | LitMetric

Purpose: To assess the correlations between preoperative Scheimpflug-based lens densitometry and effective phacoemulsification time (EPT) in age-related nuclear cataracts.

Design: Retrospective consecutive study.

Methods: The setting was the Ophthalmology Department, Hospital de Braga, Portugal. The study population included 50 eyes (42 patients) with age-related nuclear cataracts submitted to uneventful phacoemulsification surgery. Different analysis methods of Scheimpflug-based lens densitometry were performed: Pentacam Nucleus Staging (PNS) score with an ordinal scale from 0 to 5 and three-dimensional (3D), linear and region of interest (ROI) methods, which are displayed on an absolute scale (from 0 to 100%). EPT was calculated for the cataract surgery, which was performed by the same surgeon. Correlations between lens densitometry variables and EPT were determined using Pearson or Spearman correlation coefficients according to data normality.

Results: There were significant correlations between EPT and average density and maximum density variables derived from the 3D (r = 0.596, p < 0.001; r = 0.632, p < 0.001, respectively) and ROI (r = 0.527, p < 0.001; r = 0.575, p < 0.001, respectively) methods. The average density was the only parameter derived from the linear analysis that showed a significant correlation with EPT (r = 0.293, p = 0.039). The PNS score did not show a significant correlation with EPT (rho = 0.124, p = 0.390).

Conclusion: The densitometric parameters based on the 3D method showed the highest correlations with EPT. The referred lens densitometric analysis approach may be used in preoperative assessment in order to predict EPT more efficiently in age-related nuclear cataracts.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10792-017-0566-7DOI Listing

Publication Analysis

Top Keywords

lens densitometry
16
scheimpflug-based lens
12
effective phacoemulsification
8
phacoemulsification time
8
nuclear cataracts
8
age-related nuclear
8
correlation scheimpflug-based
4
lens
4
densitometry
4
densitometry analysis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!