Effect of functional appliances on the airway dimensions in patients with skeletal class II malocclusion: A systematic review.

J Orthod Sci

Department of Orthodontics and Dentofacial Orthopaedics, Faculty of Dental Sciences, Sri Ramachandra University, Chennai, Tamil Nadu, India.

Published: January 2017

Objectives: The aim of the present systematic review was to assess the effect of functional appliances on the airway dimensions in patients with skeletal Class II malocclusion.

Materials And Methods: Articles were identified through a literature survey carried out through the following databases: (1) PUBMED, (2) Google Scholar, (3) The Cochrane Library, (4) Embase, (5) Lilac, and (6) Web of Scholars. The systematic review analyzed 12 articles comprising removable functional appliances, 3 articles with fixed functional appliances, and 2 articles having both fixed and removable functional appliances.

Results: Qualitative assessment was done for all the 17 studies. The effect of functional appliances in the dimensions of three airway spaces - nasopharynx, oropharynx, and hypopharynx were analyzed.

Conclusions: Significant increase in the dimensions of nasopharynx and oropharynx was observed with Activator. Significant increase in the nasopharynx and hypopharynx (male patients) was observed with Bionator. Insignificant increase in the oropharynx was observed with the same. Significant increase in the oropharynx and hypopharynx was observed with Twin Block. Insignificant increase in the nasopharynx was observed with the same. Significant increase was observed only in the hypopharynx for Frankel II. Decreased or insignificant change was observed with FMA, MPA IV, and Herbst appliances.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5433105PMC
http://dx.doi.org/10.4103/jos.JOS_154_16DOI Listing

Publication Analysis

Top Keywords

functional appliances
20
systematic review
12
appliances airway
8
airway dimensions
8
dimensions patients
8
patients skeletal
8
skeletal class
8
removable functional
8
appliances articles
8
articles fixed
8

Similar Publications

Significance: Laparoscopic surgery is generally unavailable in low- and middle-income countries (LMICs) due to the high cost of installation and lack of qualified personnel to maintain and repair equipment. We developed a low-cost, durable, reusable laparoscopic system, called the KeyScope laparoscope, for use in LMICs. To reliably build and service the KeyScope in LMICs, a portable testing chamber (PTC) is needed to assess image performance.

View Article and Find Full Text PDF

Directed evolution of peroxidase DNAzymes by a function-based approach.

Biol Methods Protoc

December 2024

School of Biomedical Sciences, LKS Faculty of Medicine, The University of Hong Kong, Hong Kong SAR, P.R. China.

Peroxidase DNAzymes are single-stranded, stable G-quadruplexes structures that exhibit catalytic activity with cofactor hemin. This class of DNAzymes offers several advantages over traditional protein and RNA catalysts, including thermal stability, resistance to hydrolysis, and easy of synthesis in the laboratory. However, their use in medicine, biology, and chemistry is limited due to their low catalytic rates.

View Article and Find Full Text PDF

The patient's body temperature significantly fluctuates, affected by factors, including anesthesia. The ideal temperature monitoring method that is suitable for perioperative application is of great significance for identifying hypothermia and malignant hyperthermia early, as well as for guiding intraoperative temperature protection. This study aims to compare the cutaneous zero-heat-flux (ZHF) thermometer application in general anesthesia using the infrared tympanic measurement as a reference.

View Article and Find Full Text PDF

Hook plate fixation and tension band wiring in the treatment of Mayo type II olecranon fractures.

J Orthop Surg Res

January 2025

Department of Orthopedic Trauma, Beijing Jishuitan Hospital, Capital Medical University, No. 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.

Background: Olecranon fractures account for 8 ∼ 10% of all elbow fractures and usually require surgical intervention. Tension band wiring (TBW) is considered as the standard treatment while it is associated with high re-operation rates.

Objective: This study aims to compare the functional outcomes, complications and re-operations of hook plate fixation (HPF) versus TBW in treating Mayo Type II olecranon fractures.

View Article and Find Full Text PDF

Objective: To investigate the effects of modified twin-block appliances (MTBA) on obstructive sleep apnea (OSA) and mandibular retrognathia and the changes in the upper airway, hyoid bone position, and hypoxia-related inflammatory marker levels in children with OSA.

Methods: This study included children with OSA and mandibular retrognathia and those with class I without mandibular retrognathia (n = 35 each). The experimental group comprised children with OSA and mandibular retrognathia managed using MTBA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!