Current in vitro approaches to cardiac safety testing typically focus on mechanistic ion channel testing to predict in vivo proarrhythmic potential. Outside of the Comprehensive in vitro Proarrhythmia Assay (CiPA) initiative, structural and functional cardiotoxicity related to chronic dosing effects are of great concern as these effects can impact compound attrition. Development and implementation of an in vitro cardiotoxicity screening platform that effectively identifies these liabilities early in the discovery process should reduce costly attrition and decrease preclinical development time. Impedence platforms have the potential to accurately identify structural and functional cardiotoxicity and have sufficient throughput to be included in a multi-parametric optimization approach. Human induced pluripotent stem cell cardiomyocytes (hIPSC-CMs) have demonstrated utility in cardiac safety and toxicity screening. The work described here leverages these advantages to assess the predictive value of data generated by two impedance platforms. The response of hIPSC-CMs to compounds with known or predicted cardiac functional or structural toxicity was determined. The compounds elicited cardiac activities and/or effects on "macro" impedance often associated with overt structural or cellular toxicity, detachment, or hypertrophy. These assays correctly predicted in vivo cardiotox findings for 81% of the compounds tested and did not identify false positives. In addition, internal or literature C values from in vivo studies correlated within 4 fold of the in vitro observations. The work presented here demonstrates the predictive power of impedance platforms with hIPSC-CMs and provides a means toward accelerating lead candidate selection by assessing preclinical cardiac safety earlier in the drug discovery process.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.taap.2017.05.023DOI Listing

Publication Analysis

Top Keywords

cardiac safety
12
approach human
8
vivo cardiotox
8
structural functional
8
functional cardiotoxicity
8
discovery process
8
impedance platforms
8
vitro
5
cardiac
5
impedance-based approach
4

Similar Publications

We aimed to determine whether emergency department (ED) overcrowding affects the occurrence of in-hospital cardiac arrest (IHCA) requiring resuscitation in the ED. This retrospective study was conducted in the ED of a single hospital. We applied the propensity score-matching method to adjust for differences in clinical characteristics in patients who visited the ED during overcrowded conditions.

View Article and Find Full Text PDF

Aims: This post hoc analysis aimed to assess the efficacy and safety of the non-steroidal mineralocorticoid receptor antagonist finerenone by baseline diuretic use in FIDELITY, a pre-specified pooled analysis of the phase III trials FIDELIO-DKD and FIGARO-DKD.

Methods And Results: Eligible patients with type 2 diabetes (T2D) and chronic kidney disease (CKD; urine albumin-to-creatinine ratio [UACR] ≥30-<300 mg/g and estimated glomerular filtration rate [eGFR] ≥25-≤90 ml/min/1.73 m, or UACR ≥300-≤5000 mg/g and eGFR ≥25 ml/min/1.

View Article and Find Full Text PDF

The transcatheter management of complex cardiovascular diseases has significantly evolved, offering less invasive alternatives to traditional surgical interventions. In this report we describe 2 cases of patients who developed ascending aortic pseudoaneurysms soon after coronary artery bypass grafting. With meticulous computed tomography angiography planning and with live intracardiac echography, these patients underwent successful transcatheter repair using a 6/4-mm Amplatzer Duct Occluder II (Abbott) vascular plug.

View Article and Find Full Text PDF

Transcatheter mass extraction of left-sided cardiac masses has gained popularity in recent years, with scarce data on effectiveness, safety, and types of devices used. Mostly, left-sided aspirations use mechanical and continuous-flow-mediated devices (the AngioVac [AngioDynamics] and Penumbra systems [Penumbra]). To our knowledge, the use of manual aspiration devices has not been reported yet.

View Article and Find Full Text PDF

Enhancing Diagnostic Precision: Intracardiac Echocardiography-Guided Endomyocardial Biopsy for Complex Right Atrial Mass.

JACC Case Rep

December 2024

Department of Cardiology, Centro Hospitalar Universitário Lisboa Norte,Centro Cardiovascular da Universidade de Lisboa (CCUL@RISE), Faculdade de Medicina da Universidade de Lisboa, Centro Académico de Medicina de Lisboa, Lisbon, Portugal.

An 80-year-old woman with a history of B-cell non-Hodgkin lymphoma presented to the emergency department with exertional dyspnea and lower limb edema. A transthoracic echocardiogram revealed a large extracardiac mass invading the right atrium. A diagnostic transcatheter endomyocardial biopsy guided by intracardiac echocardiography was performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!