Neuro-Cardiac-Guided TMS (NCG-TMS): Probing DLPFC-sgACC-vagus nerve connectivity using heart rate - First results.

Brain Stimul

Dept. of Experimental Psychology, Utrecht University, Utrecht, The Netherlands; Research Institute Brainclinics, Nijmegen, The Netherlands; neuroCare Group, Munich, Germany.

Published: April 2018

Background: Given that many studies suggest a role of DLPFC-sgACC connectivity in depression and prior research demonstrating that neuromodulation of either of these nodes modulates parasympathetic activity and results in a heart rate deceleration, a new method is proposed to individualize localization of the DLPFC. This can, among others, be useful for rTMS treatment of depression.

Methods: Ten healthy subjects received three trains of 10Hz rTMS randomly over 7 target regions (10-20 system).

Results: Overall, F3 and F4 expressed the largest heart rate deceleration, in line with studies suggesting these are the best 10-20 sites to target the DLPFC. On the individual level, 20-40% subjects expressed the largest heart rate deceleration at FC3 or FC4, indicating individual differences as to the 'optimal site for stimulation'.

Conclusions: These results show that the NCG-TMS method is valid to localize the entry into the DLPFC-sgACC network.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.brs.2017.05.002DOI Listing

Publication Analysis

Top Keywords

heart rate
16
rate deceleration
12
expressed largest
8
largest heart
8
neuro-cardiac-guided tms
4
tms ncg-tms
4
ncg-tms probing
4
probing dlpfc-sgacc-vagus
4
dlpfc-sgacc-vagus nerve
4
nerve connectivity
4

Similar Publications

The study was designed to investigate the pattern of intraventricular Hemo-Dynamic Forces (HDF) and myocardial performance during exercise in Elite Cyclists (EC). Transthoracic stress echocardiography was performed on nineteen EC and thirteen age-matched sedentary controls (SC) at three incremental exercise intensities based on Heart Rate Reserve (HRR). Left Ventricular (LV) HDF were computed from echocardiography long-axis data sets using a novel technique based on endocardial boundary tracking, both in apex-base and latero-septal directions.

View Article and Find Full Text PDF

Outcomes of a transapical edge-to-edge repair system in secondary mitral regurgitation.

J Invasive Cardiol

January 2025

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, China; State Key Laboratory of Cardiovascular Diseases, Zhongshan Hospital, Fudan University; NHC Key Laboratory of Ischemic Heart Diseases; Key Laboratory of Viral Heart Diseases, Chinese Academy of Medical Sciences; National Clinical Research Center for Interventional Medicine, Shanghai, China.

Objectives: The ValveClamp system (Hanyu Medical Technology) is a novel transcatheter edge-to-edge repair (TEER) system designed for ease of operation; however, there is a lack of data on its application in secondary mitral regurgitation (SMR). The authors report the mid-term outcomes of TEER using the ValveClamp system in SMR.

Methods: The study prospectively analyzed consecutive severe SMR patients who underwent transapical ValveClamp implantation at 10 Chinese centers.

View Article and Find Full Text PDF

Objectives: The aim of this study was to determine the indication and optimal timing for performing a hemiarch procedure in patients undergoing valve-sparing root replacement (VSRR).

Methods: We conducted a retrospective study on 986 patients undergoing VSRR at three tertiary care centres. Inclusion criteria were all patients undergoing elective VSRR.

View Article and Find Full Text PDF

Background: Timing of treatment of aortic stenosis (AS) is of key importance. AS severity is currently determined by transthoracic echocardiography (TTE) with a main focus on mean trans-aortic gradients. However, echocardiography has its limitations.

View Article and Find Full Text PDF

Background: The prompt and accurate identification of mild cognitive impairment (MCI) is crucial for preventing its progression into more severe neurodegenerative diseases. However, current diagnostic solutions, such as biomarkers and cognitive screening tests, prove costly, time-consuming, and invasive, hindering patient compliance and the accessibility of these tests. Therefore, exploring a more cost-effective, efficient, and noninvasive method to aid clinicians in detecting MCI is necessary.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!