Background: A previously validated finite element modeling approach was used to determine how changes in glenoid component version and polyethylene liner rotation within the humeral component affect the arm abduction angle at which impingement between the inferior glenoid and the polyethylene liner occurs as well as the amount of subluxation generated by that impingement.
Materials And Methods: Five glenoid component versions (5° anteversion; neutral; 5°, 10°, and 20° retroversion) and 7 polyethylene liner rotations (20° and 10° anterior; neutral; 10°, 20°, 30°, and 40° posterior) were considered, resulting in 35 different clinically representative models. The humerus was internally and externally rotated and extended and flexed, and the resulting impingement and subluxation were measured. To further analyze more global trends and to identify implantations least prone to subluxation, polyethylene liner rotation was additionally varied in coarser 30° increments across the entire 360° range.
Results: All subluxation caused by impingement occurred during external rotation and extension, and external rotation produced nearly 10-fold more subluxation than extension. Neutral glenoid component version was associated with the least amount of subluxation for all polyethylene liner rotations. Posteriorly rotated polyethylene liners, which place the thick inferior region of the component away from the scapula, produced the least amount of subluxation. The 90° and 120° posterior liner rotations produced no subluxation, whereas the 30° and 60° anterior liner rotations produced the greatest amount of subluxation.
Conclusion: These results indicate that rotating modern radially asymmetric humeral polyethylene liners posteriorly can reduce the risk of subluxation leading to dislocation and increase external rotation range of motion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jse.2017.03.027 | DOI Listing |
J Orthop Surg Res
January 2025
Department of Orthopaedics, Liaocheng People's Hospital, Liaocheng, Shandong, P.R. China.
Background: Vitamin E-diffused highly cross-linked polyethylene (HXLPE/Vit E) is a relatively advanced material used in total hip arthroplasty (THA) but whether it shows superiority is unclear.
Objective: This meta-analysis was performed to investigate the effect of HXLPE/Vit E liners in THA.
Methods: Medline/PubMed, Embase and Cochrane Library databases were searched to retrieve studies assessing the efficacy of HXLPE/Vit E liners in THA with the design of a randomized, controlled trial.
Total knee arthroplasty (TKA) with hardware around the knee is a challenge to preserve bone while boney landmarks are distorted. Robotic assisted (RA) TKA may assist in simultaneous hardware removal and TKA due to preoperative planning and retention of bone. The aim of this study is to identify if there are differences in component fixation, component constraint and functional outcomes dependent during simultaneous removal of hardware (ROH) around the knee and TKA comparing RA-TKA to manual.
View Article and Find Full Text PDFSurg Technol Int
January 2025
JIS Orthopedics Inc., New Albany, Ohio.
Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery complications, most notably dislocation.1 Furthermore, malposition can also result in wear of the polyethylene liner, limited range of motion, and osteolysis.
View Article and Find Full Text PDFArthroplast Today
February 2025
Department of Orthopaedic Surgery, Fiona Stanley Fremantle Hospitals Group, Murdoch, Western Australia, Australia.
Background: Dual mobility (DM) implants in total hip arthroplasty provide excellent range of motion with low dislocation rates. A complication of this design is intraprosthetic dislocation (IPD), where the polyethylene (PE) liner dissociates from the femoral head. In older designs, IPD occurred due to a small head size and late PE wear with head-capture-mechanism failure.
View Article and Find Full Text PDFCureus
December 2024
Orthopedic Surgery, Tri-County Orthopedics, Bridgewater, USA.
A 73-year-old female experienced an atraumatic fracture of a BIOLOX delta ceramic femoral head following uncomplicated right total hip arthroplasty using a ceramic-on-polyethylene bearing. The fracture occurred post-operatively, as revealed by radiography after the patient reported a clunking sensation and leg shortening. Revision surgery involved replacing the fractured head and liner with careful removal of ceramic debris.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!