Selectivity and localization of lysozyme uptake in contemporary hydrogel contact lens materials.

J Biomater Sci Polym Ed

a Centre for Contact Lens Research, School of Optometry and Vision Science , University of Waterloo, Waterloo , Canada.

Published: September 2017

The purpose of this study was to investigate the early and selective uptake of lysozyme and the location of deposited lysozyme on contemporary hydrogel contact lens (CL) materials after exposure to an artificial tear solution (ATS) for 16 h. Seven different hydrogel CL materials [polymacon, omafilcon A, nelfilcon A, nesofilcon A, ocufilcon B, etafilcon A (Acuvue Moist), and etafilcon A (Acuvue Define)] were incubated in an ATS for various times. Total protein deposition was determined using a modified Bradford technique. Lysozyme, lactoferrin, and albumin deposition on CLs were determined using I-radiolabeling method. A confocal laser scanning microscopy (CLSM) technique was utilized to map the location of lysozyme uptake in an asymmetric environment. All lens materials had significant amounts of lysozyme after 1 min of exposure to ATS. After 16 h of incubation, higher levels of total protein deposited on the two etafilcon A-based lenses (Moist and Define), followed by ocufilcon B and both were significantly higher than all other CLs tested (p = 0.0001). The two etafilcon A materials (Moist and Define) also deposited the highest amounts of lysozyme (514.8 ± 28.4 and 527.1 ± 14.7 μg/lens respectively) when compared to other test CLs (p = 0.0001). The CLSM technique revealed that the non-ionic CLs tended to have symmetric distribution of lysozyme throughout the lens materials, while the ionic CLs had an asymmetric distribution, with the highest concentration of lysozyme on and near the exposed surface. The quantity and nature of proteins deposited on CLs varies, depending upon the chemical composition of the material. Among the various lenses tested, etafilcon A deposited the highest amount of total protein, most of it represented by lysozyme, which was largely located near the surface of the lens.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09205063.2017.1327751DOI Listing

Publication Analysis

Top Keywords

lens materials
16
total protein
12
lysozyme
10
lysozyme uptake
8
contemporary hydrogel
8
hydrogel contact
8
contact lens
8
ats 16 h
8
etafilcon acuvue
8
clsm technique
8

Similar Publications

This essay is an attempt to determine what Robert Bernasconi's body of work in Critical Philosophy of Race can teach us about the way in which we, philosophers and professors of philosophy, ought to treat our institutional heritage. What should we make, for instance, of moral claims made by philosophers of the modern era who - tacitly or explicitly - manifested certain levels of endorsement toward the Atlantic Slave Trade? How should we comprehend the conceptual tools that we have inherited from them, knowing that those were formulated alongside justificatory claims for the enslavement of Africans - claims that we now deem undoubtably and universally immoral? I extract from Bernasconi's writings an implicit methodology that can be broken down into three main moves: (1) a historiographical work, akin to Michel Foucault's 'archaeological' method, aimed at uncovering the material conditions that allowed for the emergence of philosophical ideas of the past, (2) a dialectical work aimed at interpreting this collection of historical data through the critical lens of race, and (3) a pedagogical work aimed at transforming the practice of academic philosophy in light of the critique. I conclude that his methodological contribution culminates in an invitation to revisit and transform the past of the institution by treating the history of academic philosophy as philosophically and conceptually relevant rather than merely incidental.

View Article and Find Full Text PDF

Inverse design with topology optimization considers a promising methodology for discovering new optimized photonic structure that enables to break the limitations of the forward or the traditional design especially for the meta-structure. This work presents a high efficiency mid infra-red imaging photonics element along mid infra-red wavelengths band starts from 2 to 5 µm based on silicon nitride optimized material structures. The first two designs are broadband focusing and reflective meta-lens under very high numerical aperture condition (NA = 0.

View Article and Find Full Text PDF

The emerging field of 3D organ modeling encounters several imaging issues in particular related to antigen retrieval and sample loss during staining processes. Due to their compact shape, several antibodies fail to penetrate intact organoids or spheroids. Histology of organoids can be approached by paraffin inclusion and sectioning at 5 μm as performed for biopsies.

View Article and Find Full Text PDF

A decade of intracapsular cataract extraction: Clinical profile and visual outcomes at Hospital Melaka, Malaysia.

Med J Malaysia

January 2025

Universiti Sains Malaysia, School of Medical Sciences, Department of Ophthalmology and Visual Science, Health Campus, Kubang Kerian, Kelantan, Malaysia.

Introduction: Cataract is a leading cause of visual impairment globally and in Malaysia, with surgery being the definitive treatment. While intracapsular cataract extraction (ICCE) is now less commonly performed due to advancements in surgical techniques, it remains essential in specific cases, such as those with weak zonular support. This study aims to evaluate the incidence, clinical profiles, and visual outcomes of patients who underwent ICCE, with or without intraocular lens (IOL) implantation, at Hospital Melaka, Malaysia, over the past decade.

View Article and Find Full Text PDF

Background: This study aimed to explore behaviour of practitioners in response to the COVID-19 pandemic, analysing the factors that influenced their decisions to resume professional practice post-lockdown and intention to adhere to COVID-19 protective measures.

Methods: A web-based cross-sectional survey targeting Italian practitioners was carried out to study the post lockdown behaviour and future intention to provide new contact lens (CL) fittings, and the use of protective measures. The survey also explored the dimensions of the Integrated Behavioural Model (IBM) and the Health Belief Model (HBM) to predict the intention to resume professional practice and to comply with protective measures respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!