Amid growing efforts to advance the replacement, reduction, and refinement of the use of animals in research, there is a growing recognition that in vitro testing of medical devices can be more effective, both in terms of cost and time, and also more reliable than in vivo testing. Although the technological landscape has evolved rapidly in support of these concepts, regulatory acceptance of alternative testing methods has not kept pace. Despite the acceptance by regulators of some in vitro tests (cytotoxicity, gene toxicity, and some hemocompatibility assays), many toxicity tests still rely on animals (irritation, sensitization, acute toxicity, reproductive/developmental toxicity), even where other industrial sectors have already abandoned them. Bringing about change will require a paradigm shift in current approaches to testing - and a concerted effort to generate better data on risks to human health from exposure to leachable chemicals from medical devices, and to boost confidence in the use of alternative methods to test devices. To help advance these ideas, stir debate about best practices, and coalesce around a roadmap forward, the JHU-Center for Alternatives to Animal Testing (CAAT) hosted a symposium believed to be the first gathering dedicated to the topic of in vitro testing of medical devices. Industry representatives, academics, and regulators in attendance presented evidence to support the unique strengths and challenges associated with the approaches currently in use as well as new methods under development, and drew next steps to push the field forward from their presentations and discussion.

Download full-text PDF

Source
http://dx.doi.org/10.14573/altex.1608081DOI Listing

Publication Analysis

Top Keywords

medical devices
12
paradigm shift
8
vitro testing
8
testing medical
8
testing
7
vivo vitro
4
medical
4
vitro medical
4
medical device
4
device testing
4

Similar Publications

Trigger valves are fundamental features in capillary-driven microfluidic systems that stop fluid at an abrupt geometric expansion and release fluid when there is flow in an orthogonal channel connected to the valve. The concept was originally demonstrated in closed-channel capillary circuits. We show here that trigger valves can be successfully implemented in open channels.

View Article and Find Full Text PDF

An fMRI study on the generalization of motor learning after brain actuated supernumerary robot training.

NPJ Sci Learn

December 2024

Academy of Medical Engineering and Translational Medicine (AMT), Tianjin University, Tianjin, China.

Generalization is central to motor learning. However, few studies are on the learning generalization of BCI-actuated supernumerary robotic finger (BCI-SRF) for human-machine interaction training, and no studies have explored its longitudinal neuroplasticity mechanisms. Here, 20 healthy right-handed participants were recruited and randomly assigned to BCI-SRF group or inborn finger group (Finger) for 4-week training and measured by novel SRF-finger opposition sequences and multimodal MRI.

View Article and Find Full Text PDF

Nonthermal plasma has been extensively utilized in various biomedical fields, including surface engineering of medical implants to enhance their biocompatibility and osseointegration. To ensure robustness and cost effectiveness for commercial viability, stable and effective plasma is required, which can be achieved by reducing gas pressure in a controlled volume. Here, we explored the impact of reduced gas pressure on plasma properties, surface characteristics of plasma-treated implants, and subsequent biological outcomes.

View Article and Find Full Text PDF

Electrical excitability of neuronal networks based on the voltage threshold of electrical stimulation.

Sci Rep

December 2024

State Key Laboratory of Digital Medical Engineering, Southeast University, Nanjing, 210096, China.

Microelectrode arrays (MEAs) have been widely used in studies on the electrophysiological features of neuronal networks. In classic MEA experiments, spike or burst rates and spike waveforms are the primary characteristics used to evaluate the neuronal network excitability. Here, we introduced a new method to assess the excitability using the voltage threshold of electrical stimulation.

View Article and Find Full Text PDF

Prognostic role of aetiological agent vs. clinical pattern in candidates to lead extraction for cardiac implantable electronic device infections.

Sci Rep

December 2024

Department of Medical and Surgical Sciences, Institute of Cardiology, University of Bologna, Policlinico S.Orsola-Malpighi, via Massarenti 9, Bologna, 40138, Italy.

Cardiac implantable electronic devices infections (CIEDI) are associated with poor survival despite the improvement in transvenous lead extraction (TLE). Aetiology and systemic involvement are driving factors of clinical outcomes. The aim of this study was to explore their contribute on overall mortality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!