Reliability and Accuracy of a Standardized Shallow Water Running Test to Determine Cardiorespiratory Fitness.

J Strength Cond Res

1Department of Health and Physical Activity, University of Pittsburgh, Pittsburgh, Pennsylvania; 2Division of Endocrinology and Wellness & Weight Management, School of Medicine, University of Nevada, Reno, Nevada; 3Preventive Cardiology and Cardiac Rehabilitation, William Beaumont Hospital, Royal Oak, Michigan; 4Department of Exercise Science, Physical Education and Sport Studies, John Carroll University, University Heights, Ohio; 5Department of Exercise Science and Athletics, Grove City College, Grove City, Pennsylvania; and the Departments of 6Health and Rehabilitative Sciences; and 7Health and Physical Activity, University of Pittsburgh, Pittsburgh, Pennsylvania.

Published: June 2017

A standardized fitness assessment is critical for the development of an individualized exercise prescription. Although the benefits of aquatic exercise have been well established, there remains the need for a standardized nonswimming protocol to accurately assess cardiorespiratory fitness (CRF) in shallow water. The present investigation was designed to assess (a) the reliability of a standardized shallow water run (SWR) test of CRF and (b) the accuracy of a standardized SWR compared with a land-based treadmill (LTM) test. Twenty-three healthy women (20 ± 3 years), with body mass index (23.5 ± 3 kg·m), performed 2 shallow water peak oxygen consumption (V[Combining Dot Above]O2peak) running tests (SWRa and SWRb), and 1 V[Combining Dot Above]O2max LTM. Intraclass correlation coefficients indicated moderately strong reliability for V[Combining Dot Above]O2peak (ml·kg·min) (r = 0.73, p < 0.01), HRpeak (b·min) (r = 0.82; p < 0.01), and O2pulse (V[Combining Dot Above]O2 [ml·kg·min]·HR [b·min]) (r = 0.77, p < 0.01). Using paired t-tests and Pearson's correlations, SWR V[Combining Dot Above]O2peak and HRpeak were significantly lower than during LTM (p ≤ 0.05) and showed moderate correlations of 0.60 and 0.58 (p < 0.001) to LTM. O2pulse was similar (p > 0.05) for the SWR and LTM tests with a moderate correlation of 0.63. A standardized SWR test as a measure of CRF is a reliable, and to some degree, valid alternative to conventional protocols and may be used by strength and conditioning professionals to measure program outcomes and monitor training progress. Furthermore, this protocol provides a water-based option for CRF assessment among healthy women and offers insight toward the development of an effective protocol that can accommodate individuals with limited mobility, or those seeking less musculoskeletal impact from traditional land-based types of training.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0000000000001638DOI Listing

Publication Analysis

Top Keywords

v[combining dot
20
shallow water
16
dot above]o2peak
12
accuracy standardized
8
standardized shallow
8
cardiorespiratory fitness
8
swr test
8
standardized swr
8
healthy women
8
standardized
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!