Risk management and regulations for lower limb medical exoskeletons: a review.

Med Devices (Auckl)

Laboratory for Noninvasive, Brain-Machine Interface Systems, Department of Electrical and Computer Engineering, University of Houston, Houston, TX, USA.

Published: May 2017

Gait disability is a major health care problem worldwide. Powered exoskeletons have recently emerged as devices that can enable users with gait disabilities to ambulate in an upright posture, and potentially bring other clinical benefits. In 2014, the US Food and Drug Administration approved marketing of the ReWalk™ Personal Exoskeleton as a class II medical device with special controls. Since then, Indego™ and Ekso™ have also received regulatory approval. With similar trends worldwide, this industry is likely to grow rapidly. On the other hand, the regulatory science of powered exoskeletons is still developing. The type and extent of probable risks of these devices are yet to be understood, and industry standards are yet to be developed. To address this gap, Manufacturer and User Facility Device Experience, Clinicaltrials.gov, and PubMed databases were searched for reports of adverse events and inclusion and exclusion criteria involving the use of lower limb powered exoskeletons. Current inclusion and exclusion criteria, which can determine probable risks, were found to be diverse. Reported adverse events and identified risks of current devices are also wide-ranging. In light of these findings, current regulations, standards, and regulatory procedures for medical device applications in the USA, Europe, and Japan were also compared. There is a need to raise awareness of probable risks associated with the use of powered exoskeletons and to develop adequate countermeasures, standards, and regulations for these human-machine systems. With appropriate risk mitigation strategies, adequate standards, comprehensive reporting of adverse events, and regulatory oversight, powered exoskeletons may one day allow individuals with gait disabilities to safely and independently ambulate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5431736PMC
http://dx.doi.org/10.2147/MDER.S107134DOI Listing

Publication Analysis

Top Keywords

powered exoskeletons
20
probable risks
12
adverse events
12
lower limb
8
gait disabilities
8
medical device
8
inclusion exclusion
8
exclusion criteria
8
exoskeletons
6
powered
5

Similar Publications

Stroke is a leading cause of disability worldwide, driving the need for advanced rehabilitation strategies. The integration of Artificial Intelligence (AI) into stroke rehabilitation presents significant advancements across the continuum of care, from acute diagnosis to long-term recovery. This review explores AI's role in stroke rehabilitation, highlighting its impact on early diagnosis, motor recovery, and cognitive rehabilitation.

View Article and Find Full Text PDF

Humans rely on ankle torque to maintain standing balance, particularly in the presence of small to moderate perturbations. Reductions in maximum torque (MT) production and maximum rate of torque development (MRTD) occur at the ankle with age, diminishing stability. Ankle exoskeletons are powered orthotic devices that may assist older adults by compensating for reduced torque and power production capabilities.

View Article and Find Full Text PDF

Objectives: In view of the gradual rejuvenation and acceleration of lumbar spondylosis, a wearable powered lumbar exoskeleton based on a 6-SPU/SP parallel mechanism is designed based on the rehabilitation treatment method of lumbar forward flexion/extension, left/right lateral flexion and rotation.

Methods: First, the changes in human lumbar muscles are analyzed based on human biomechanics, and then the prototype design of the powered lumbar exoskeleton is implemented, including the mechanical mechanism design, and hardware module design. Finally, the simulation experiment of muscle force and output sensitivity test in the resistive mode are conducted.

View Article and Find Full Text PDF

Hand exoskeletons have been developed to assist the grasping of people with hand dysfunction in daily activities and rehabilitation. However, there are challenges with weight, portability, and the use of the hand's tactile sensation and friction. This paper reports on a lightweight, portable, flexible hand exoskeleton to assist grasping.

View Article and Find Full Text PDF

In powered lower limb prostheses and exoskeleton control, sEMG based methods have been widely explored and utilized due to non-invasive nature and ability to directly reflect user intentions. However, in practical use, neuromuscular fatigue (NMF) caused by long-term use can cause significant changes in sEMG signals. These issues are constraining sEMG's active prosthetics from the laboratory to real life.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!