New flexible endoscopic controlled stapler technique for the treatment of Zenker's diverticulum: A case series.

World J Gastroenterol

Johanna Wilmsen, Robert Baumbach, Siegbert Faiss, Department of Gastroenterology and Interventional Endoscopy, Asklepios Hospital Barmbek, Semmelweis University, Medical Faculty, Campus Hamburg, 22291 Hamburg, Germany.

Published: May 2017

Aim: To report about the combination and advantages of a stapler-assisted diverticulotomy performed by flexible endoscopy.

Methods: From November 2014 till December 2015 17 patients (8 female, 9 male, average age 69.8 years) with a symptomatic Zenker diverticulum (mean size 3.5 cm) were treated by inserting a new 5 mm fully rotatable surgical stapler (MicroCutter30 Xchange, Cardica Inc.) next to an ultrathin flexible endoscope through an overtube. The Patients were under conscious sedation with the head reclined in left position, the stapler placed centrally and pushed forward to the bottom of the diverticulum. The septum was divided by the staple rows under flexible endoscopic control.

Results: In eleven patients (64.7%) the stapler successfully divided the septum completely. Mean procedure time was 21 min, medium size of the septum was 2.8 cm (range 1.5 cm to 4 cm). In four patients the septum was shorter than 3 cm, in seven longer than 3 cm. To divide the septum, averagely 1.3 stapler cartridges were used. Two minor bleedings occurred. Major adverse events like perforation or secondary haemorrhage did not occur. After an average time of two days patients were discharged from the hospital. In 6 patients (35.3%) the stapler failed due to a thick septum or insufficient reclination of the head. Follow up endoscopy was performed after an average of two months in 9 patients; 4 patients (44.4%) were free of symptoms, 5 patients (55.6%) stated an improvement. A relapse of symptoms did not occur.

Conclusion: Flexible endoscopic Zenker diverticulotomy by using a surgical stapler is a new, safe and efficient treatment modality. A simultaneously tissue opening and occlusion prevents major complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5423045PMC
http://dx.doi.org/10.3748/wjg.v23.i17.3084DOI Listing

Publication Analysis

Top Keywords

flexible endoscopic
12
patients
9
surgical stapler
8
stapler
7
septum
6
flexible
5
endoscopic controlled
4
controlled stapler
4
stapler technique
4
technique treatment
4

Similar Publications

Currently, Unilateral biportal endoscopy is widely used in the surgical treatment of lumbar spinal stenosis. To investigate the feasibility of bilateral synchronous UBE to unilateral laminotomy and bilateral decompression(BS-UBE-ULBD) for treating two-level lumbar spinal stenosis (LSS). Sixty-four patients with two-level lumbar spinal stenosis (LSS) treated with BS-UBE-ULBD from October 2022 to January 2024 were retrospectively analyzed.

View Article and Find Full Text PDF

Background: Foreign body inhalation is rare in older children, often leading to underdiagnosis and delayed treatment. Most cases involve a single foreign body, but instances of multiple foreign bodies are exceedingly uncommon. This report presents a case of an elder child who inhaled two pen caps, emphasizing the need for clinical vigilance and thorough medical history collection.

View Article and Find Full Text PDF

Purpose: To report on in-vivo intrarenal pressure (IRP) during flexible ureteroscopy for treatment of kidney stones while using the novel flexible and navigable suction ureteral access sheath (FANS).

Methods: A retrospective observational analysis was performed for 25 patients undergoing routine flexible ureteroscopy for treatment of renal stones between February 2024 and June 2024 from two centres in Canada. The LithoVue Elite™ ureteroscope (Boston Scientific Corp.

View Article and Find Full Text PDF

Since abdominal adhesion are quite problematic in abdominal and pelvic surgery, the conventional HA/CMC film are commonly used as an anti-adhesive material. However, such types are difficult to be rolled and delivered through the port of laparoscopic surgical devices due to adherence to the laparoscopic port or other parts of the films. To create an anti-adhesion film with more favorable handling properties and anti-adhesive effect, we developed a novel punctate uneven gelatin film (PU GF).

View Article and Find Full Text PDF

When a difficult airway is anticipated, awake tracheal intubation can be considered. Usually, low doses of sedatives are administered during this procedure for minimal sedation and anxiolysis, such as midazolam and remifentanil. The newly developed ultra-short-acting benzodiazepine remimazolam has a pharmacokinetic profile that is more suitable for titration during awake tracheal intubation than the long-acting midazolam.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!