Objectives Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcation configuration in vivo. Methods Post-operative computed tomographic data and patient demographics from 11 covered endovascular reconstruction of the aortic bifurcation and 11 matched kissing stent patients were included. A free hand region of interest and ellipse fitting method were applied to determine mismatch areas and volumes. Conformation of the stents to the vessel wall was expressed using the D-ratio. Results Patients were mostly treated for Rutherford category 2 and 3 (64%) with a lesion classification of TASC C and D in 82%. Radial mismatch area and volume for the covered endovascular reconstruction of the aortic bifurcation group was significantly lower compared to the kissing stent configuration ( P < 0.05). The D-ratio did not significantly differ between groups. Measurements were performed with good intra-class correlation. There were no significant differences in the post-procedural aortoiliac anatomy. Conclusions The present study shows that radial mismatch exists in vivo and that large differences in mismatch exist, in favour of the covered endovascular reconstruction of the aortic bifurcation configuration. Future research should determine if the decreased radial mismatch results in improved local flow profiles and subsequent clinical outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714162PMC
http://dx.doi.org/10.1177/1708538117708912DOI Listing

Publication Analysis

Top Keywords

kissing stent
20
covered endovascular
20
endovascular reconstruction
20
reconstruction aortic
20
aortic bifurcation
20
stent covered
8
bifurcation configuration
8
kissing
5
stent
5
covered
5

Similar Publications

Limited evidence exists regarding the long-term outcomes of true versus nontrue coronary bifurcation lesions (CBLs) treated with current-generation drug-eluting stents and intravascular imaging guidance. The Sapporo Cardiovascular Clinic (SCVC) registry was a prospective, single-center, all-comers registry enrolling 1,727 consecutive patients treated with bioresorbable polymer sirolimus-eluting stent under complete imaging guidance. From this registry, 440 patients with CBLs (25.

View Article and Find Full Text PDF

The double-kissing (DK) culotte technique is a modification of the culotte technique that employs initial kissing balloon inflation after first stent implantation. The DK culotte technique may improve strut apposition and procedural outcomes; however, data on its efficacy and safety remain limited. This study aimed to investigate the short-term outcomes of bifurcation percutaneous coronary intervention (PCI) using the DK culotte technique compared with those of the culotte technique in patients with acute coronary syndrome (ACS).

View Article and Find Full Text PDF

Phlegmasia cerulea dolens is a rare manifestation of massive deep vein thrombosis with threat to limb and life. A patient with a background of ovarian malignancy in remission and pelvic radiotherapy presented with left lower limb phlegmasia cerulea dolens as a result of extensive acute left lower limb deep vein thrombosis, extending from the popliteal vein to the inferior vena cava. While initial rapid thrombolysis and left iliac vein stenting were successful, she developed significant hemorrhagic complications from her right radial intra-arterial line with compartment syndrome requiring fasciotomy.

View Article and Find Full Text PDF

Background: Endovascular therapy is an effective method for revascularization in lower extremity artery disease, but treating chronic total occlusion (CTO) remains challenging. This is particularly true for patients with severe calcification, poor run-off in below-the-knee arteries, or limited access sites, where even guidewire (GW) passage can be difficult and bidirectional approaches are often not feasible. The tip-detection (TD) method has been reported as a useful technique in coronary artery CTO interventions, allowing real-time visualization of the GW tip direction.

View Article and Find Full Text PDF

Impact of intravascular ultrasound for coronary bifurcations treated with last generations stents: insights from the BIFURCAT-ULTRA registry.

Eur Heart J Qual Care Clin Outcomes

November 2024

Division of Cardiology, Cardiovascular and Thoracic Department, A.O.U Città della Salute e della Scienza, Turin, Italy.

Background: Bifurcation lesions are associated with higher rates of major adverse cardiovascular events (MACE).

Aim: To investigate the impact of imaging-guided PCI in a real-world population with coronary bifurcation lesions.

Methods: From the ULTRA-BIFURCAT registry, we compared IVUS vs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!