In dynamic multi-leaf collimator (MLC) intensity-modulated radiotherapy (IMRT), the accuracy of delivered dose is influenced by the positional accuracy of the moving MLC. In order to assess the accuracy of the delivered dose during dynamic MLC IMRT, the delivered dose error in dynamic MLC IMRT using the MLC speed control with dose rate change was investigated. Sweeping gap sequence irradiation was performed with constant MLC leaf speed at 0.6 to 5 cm/s or changed MLC speed (4 steps). The positional accuracy of the moving MLC was evaluated from the trajectory log file. Absorbed dose measurements with sweeping field (Field size: 10 cm×10 cm, MLC leaf speed: 0.6 to 2.7 cm/s, MLC leaf gap width: 0.2 to 2.0 cm) were performed. The delivered dose error at each gap width was evaluated according to MLC leaf speed change. MLC positional errors and changes in delivered dose according to MLC leaf speed were within 0.07 mm and 0.6%, respectively, for all measurements. Beam hold-off did not occur under any conditions. We confirmed that TrueBeam can regulate MLC leaf speed below the maximum limit (2.5 cm/s) by changing the dose rate in real-time during irradiation in dynamic MLC IMRT. MLC gap error during irradiation was estimated within 0.2 mm at the maximum dose rate from the results of absolute dose measurements using dynamic MLC irradiation. In conclusion, TrueBeam can use the maximum dose rate for the treatment planning of dynamic MLC IMRT, which has an advantage of shorter treatment time.

Download full-text PDF

Source
http://dx.doi.org/10.6009/jjrt.2017_JSRT_73.5.382DOI Listing

Publication Analysis

Top Keywords

dynamic mlc
24
mlc leaf
24
mlc
20
mlc imrt
20
dose rate
20
delivered dose
20
leaf speed
20
dose error
12
imrt mlc
12
mlc speed
12

Similar Publications

intra-arc binary collimation (iABC) is a novel treatment technique in which dynamic conformal arcs are periodically interrupted with binary collimation. It has demonstrated its utility through planning studies for the treatment of multiple metastases. However, the binary collimation approach is idealized in the planning system, while the treatment deliveries must adhere to the physical limitations of the mechanical systems involved [e.

View Article and Find Full Text PDF
Article Synopsis
  • Dynamic conformal arc therapy (DCAT) and volumetric modulated arc therapy (VMAT) both provide similar quality for treating brain metastases, but this study focused on how MLC errors during treatment affect dose distribution.
  • Researchers created reference plans and simulated MLC errors using a head phantom, analyzing how these errors influenced dose delivery to the targets and surrounding brain tissue.
  • The findings revealed that while MLC errors affected both techniques' dose distribution similarly, the DCAT technique showed greater resilience, with less variation in target doses compared to VMAT.
View Article and Find Full Text PDF

In this letter, we investigated the impact of percolation transport mechanisms on ferroelectric field effect transistor (FeFET) multi-value storage with Kinetic Monte-Carlo (KMC) simulation considering aspect ratio and temperature dependencies. It is found that the portion of the ferroelectric polarization, which dominated the threshold voltage shift of the FeFET, increases when aspect ratio of device decreases. Moreover, randomness of percolation path formation and variations of equivalent conductance can be suppressed, indicating mitigation of device-to-device variations and enhancement of separation of individual states.

View Article and Find Full Text PDF

O-GlcNAcylation in ovarian tumorigenesis and its therapeutic implications.

Transl Oncol

January 2025

Department of Obstetrics and Gynecology, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, China. Electronic address:

Ovarian cancer is a prevalent malignancy among women, often associated with a poor prognosis. Post-translational modifications (PTMs), particularly O-GlcNAcylation, have been implicated in the progression of ovarian cancer. Emerging evidence indicates that dysregulation of O-GlcNAcylation contributes to the initiation and malignant progression of ovarian cancer.

View Article and Find Full Text PDF

Design and performance of a novel multi-leaf collimator composed of leaves with fixed and movable layers.

Med Phys

January 2025

Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Background: The multi-leaf collimator (MLC) is an advanced device utilized for beam shaping and intensity modulation in radiotherapy. With the framework of the contemporary single-layer MLC featuring a rounded leaf tip, the leaf tip transmission and leakage exert a considerable influence on radiotherapy.

Purpose: To scale down the leakage and transmission from the leaf gap when the opposite leaves are closed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!