Purpose: The goal of this study was to compare the accuracy of a novel intraoperative cone beam computed tomography (CBCT) imaging technique with that of conventional computed tomography (CT) scans for assessment of pedicle screw placement and breach detection.
Methods: Three hundred and forty-eight pedicle screws were inserted in 58 patients between October 2013 and March 2016. All patients had an intraoperative CBCT scan and a conventional CT scan to verify the placement of the screws. The CBCT and CT images were reviewed by two surgeons to assess the accuracy of screw placement and detect pedicle breaches using two established classification systems. Agreement on screw placement between intraoperative CBCT and postoperative CT was assessed using Kappa and Gwet's coefficients. Using CT scanning as the gold standard, the sensitivity, specificity, positive predictive value, and negative predictive value were calculated to determine the ability of CBCT imaging to accurately evaluate screw placement.
Results: The Kappa coefficient was 0.78 using the Gertzbein classification and 0.80 using the Heary classification, indicating a substantial agreement between the intraoperative CBCT and postoperative CT images. Gwet's coefficient was 0.94 for both classifications, indicating almost perfect agreement. The sensitivity, specificity, positive predictive value and negative predictive value of the CBCT images were 77, 98, 86, and 96%, respectively, for the Gertzbein classification and 79, 98, 88, and 96%, respectively, for the Heary classification.
Conclusions: Intraoperative CBCT provides accurate assessment of pedicle screw placement and enables intraoperative repositioning of misplaced screws. This technique may make postoperative CT imaging unnecessary.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00586-017-5139-y | DOI Listing |
Cureus
November 2024
Aerospace Engineering, Universiti Putra Malaysia, Kuala Lumpur, MYS.
Introduction Spinal fusion surgery with pedicle screws is commonly performed to stabilize the spine of osteoporotic patients. However, securing a strong screw fixation in osteoporotic bone presents significant challenges due to the reduced bone density. This study aimed to compare the biomechanical performance in an osteoporotic bone model of pedicle screws inserted using two different techniques, the Jamshidi needle technique and the pedicle probe technique, as well as the influence of tapping on both these techniques.
View Article and Find Full Text PDFCureus
November 2024
CISNE Spine Academy, Star Medica Hospital, Autonomous University of Chihuahua, Chihuahua, MEX.
Study Design: This is a cross-sectional survey.
Objectives: This study aimed to evaluate the availability and knowledge of navigation technologies for educational purposes and patient management in spine surgeons in Latin America.
Methods: A cross-sectional study was conducted among Latin American Spine Association members using a comprehensive 16-question survey to evaluate their knowledge and practices regarding navigation in spinal surgery.
Oper Orthop Traumatol
December 2024
Department for Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital LUKS, Spitalstrasse, Lucerne, Switzerland.
Objective: To maximize local tumor control, stabilize affected bones, and preserve or replace joints with minimal interventional burden, thereby enhancing quality of life for empowered living.
Indications: Suitable for patients with bone metastases, particularly those with severe pain and/or fractures and appropriate life expectancy.
Contraindications: In primary bone tumors, refer to the sarcoma surgery team for evaluation of wide resection.
Plast Aesthet Nurs (Phila)
December 2024
Sowmya Srinivas, BDS, MDS, PhD, is an Assistant Professor at the Department of Prosthodontics, JSS Dental College and Hospital, JSS Academy of Higher Education and Research, Mysore, Karnataka, India.
Placing an implant immediately into extraction sockets provides a distinct advantage over delayed placement, eliminating the need for a 4 to 6 months waiting period for bone formation. However, when patients present with hypothyroidism, the feasibility of immediate placement of dental implants becomes uncertain. This case involved a hypothyroid woman in her late 60s with loose lower anterior teeth.
View Article and Find Full Text PDFInt J Spine Surg
December 2024
Spine Team, Division of Orthopedic Surgery and Musculoskeletal Trauma Care, Geneva University Hospitals, Faculty of Medecine, University of Geneva, Geneva, Switzerland
Background: Navigation increases the precision and safety of pedicle screw placement and has been used to place interbody cages for lateral lumbar interbody fusion. Single-position surgery shortens its duration and that of anesthesia. The aim of this study was the feasibility of simultaneous cage and screw placement in a single prone position using intraoperative navigation without the need for additional fluoroscopy and a detailed technical description of this procedure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!