Quantitative DLA-based compressed sensing for T-weighted acquisitions.

J Magn Reson

NeuroSpin, CEA Saclay, 91191 Gif-sur-Yvette, France; University Paris-Saclay, XI, 91450 Orsay, France. Electronic address:

Published: August 2017

High resolution Manganese Enhanced Magnetic Resonance Imaging (MEMRI), which uses manganese as a T contrast agent, has great potential for functional imaging of live neuronal tissue at single neuron scale. However, reaching high resolutions often requires long acquisition times which can lead to reduced image quality due to sample deterioration and hardware instability. Compressed Sensing (CS) techniques offer the opportunity to significantly reduce the imaging time. The purpose of this work is to test the feasibility of CS acquisitions based on Diffusion Limited Aggregation (DLA) sampling patterns for high resolution quantitative T-weighted imaging. Fully encoded and DLA-CS T-weighted images of Aplysia californica neural tissue were acquired on a 17.2T MRI system. The MR signal corresponding to single, identified neurons was quantified for both versions of the T weighted images. For a 50% undersampling, DLA-CS can accurately quantify signal intensities in T-weighted acquisitions leading to only 1.37% differences when compared to the fully encoded data, with minimal impact on image spatial resolution. In addition, we compared the conventional polynomial undersampling scheme with the DLA and showed that, for the data at hand, the latter performs better. Depending on the image signal to noise ratio, higher undersampling ratios can be used to further reduce the acquisition time in MEMRI based functional studies of living tissues.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2017.05.002DOI Listing

Publication Analysis

Top Keywords

compressed sensing
8
t-weighted acquisitions
8
high resolution
8
fully encoded
8
quantitative dla-based
4
dla-based compressed
4
t-weighted
4
sensing t-weighted
4
acquisitions high
4
resolution manganese
4

Similar Publications

We propose and demonstrate a photonic compressive sensing (PCS) scheme for microwave signals using optical pulse random mixing, significantly enhancing both the compression ratio and operating frequency range. Unlike continuous-wave laser-based PCS systems, our approach mitigates the non-ideal characteristics of the pseudo-random binary sequence (PRBS), such as sloped edges and amplitude jitters, resulting in a more ideal compression process. Additionally, the high harmonic components of the optical pulses further facilitate wideband downconversion, improving the system's operating frequency range.

View Article and Find Full Text PDF

Aims: The aim of this study was to develop an ultra-short echo time 3D magnetic resonance imaging (MRI) method for imaging subacute myocardial infarction (MI) quantitatively and in an accelerated way. Here, we present novel 3D T- and T -weighted Multi-Band SWeep Imaging with Fourier Transform and Compressed Sensing (MB-SWIFT-CS) imaging of subacute MI in mice hearts .

Methods And Results: Relaxation time-weighted and under-sampled 3D MB-SWIFT-CS MRI were tested with manganese chloride (MnCl) phantom and mice MI model.

View Article and Find Full Text PDF

Purpose: To develop a rapid, high-resolution and distortion-free quantitative $R_{2}^{*}$ mapping technique for fetal brain at 3 T.

Methods: A 2D multi-echo radial FLASH sequence with blip gradients is adapted for fetal brain data acquisition during maternal free breathing at 3 T. A calibrationless model-based reconstruction with sparsity constraints is developed to jointly estimate water, fat, $R_{2}^{*}$ and $B_{0}$ field maps directly from the acquired k-space data.

View Article and Find Full Text PDF

Compressive electron backscatter diffraction imaging.

J Microsc

January 2025

Department of Mechanical, Materials and Aerospace Engineering, University of Liverpool, Liverpool, UK.

Electron backscatter diffraction (EBSD) has developed over the last few decades into a valuable crystallographic characterisation method for a wide range of sample types. Despite these advances, issues such as the complexity of sample preparation, relatively slow acquisition, and damage in beam-sensitive samples, still limit the quantity and quality of interpretable data that can be obtained. To mitigate these issues, here we propose a method based on the subsampling of probe positions and subsequent reconstruction of an incomplete data set.

View Article and Find Full Text PDF

Transferring knowledge learned from standard GelSight sensors to other visuotactile sensors is appealing for reducing data collection and annotation. However, such cross-sensor transfer is challenging due to the differences between sensors in internal light sources, imaging effects, and elastomer properties. By understanding the data collected from each type of visuotactile sensors as domains, we propose a few-sample-driven style-to-content unsupervised domain adaptation method to reduce cross-sensor domain gaps.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!