Within the last three decades Scanning Probe Microscopy has been developed to a powerful tool for measuring surfaces and their properties on an atomic scale such that users can be found nowadays not only in academia but also in industry. This development is still pushed further by researchers, who continuously exploit new possibilities of this technique, as well as companies that focus mainly on the usability. However, although imaging has become significantly easier, the time required for a safe approach (without unwanted tip-sample contact) can be very time consuming, especially if the microscope is not equipped or suited for the observation of the tip-sample distance with an additional optical microscope. Here we show that the measurement of the absolute tip-sample capacitance provides an ideal solution for a fast and reliable pre-approach. The absolute tip-sample capacitance shows a generic behavior as a function of the distance, even though we measured it on several completely different setups. Insight into this behavior is gained via an analytical and computational analysis, from which two additional advantages arise: the capacitance measurement can be applied for observing, analyzing, and fine-tuning of the approach motor, as well as for the determination of the (effective) tip radius. The latter provides important information about the sharpness of the measured tip and can be used not only to characterize new (freshly etched) tips but also for the determination of the degradation after a tip-sample contact/crash.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2017.05.009DOI Listing

Publication Analysis

Top Keywords

tip-sample capacitance
12
fast reliable
8
reliable pre-approach
8
scanning probe
8
absolute tip-sample
8
tip-sample
6
pre-approach scanning
4
probe microscopes
4
microscopes based
4
based tip-sample
4

Similar Publications

The scanning capacitance microscope (SCM) is a powerful tool to characterise local electrical properties in GaN-based high electron mobility transistor (HEMT) structures with nanoscale resolution. We investigated the experimental setup and the imaging conditions to optimise the SCM contrast. As to the experimental setup, we show that the desired tip should be sharp (e.

View Article and Find Full Text PDF

A simple implementation of Kelvin probe force microscopy (KPFM) is reported that enables recording topographic images in the absence of any component of the electrostatic force (including the static term). Our approach is based on a close loop z-spectroscopy operated in data cube mode. Curves of the tip-sample distance as a function of time are recorded onto a 2D grid.

View Article and Find Full Text PDF

Electrochemical strain microscopy (ESM) is a distinguished method to characterize Li-ion mobility in energy materials with extremely high spatial resolution. The exact origin of the cantilever deflection when the technique is applied on solid state electrolytes (SSEs) is currently discussed in the literature. Understanding local properties and influences on ion mobility in SSEs is of utmost importance to improve such materials for next generation batteries.

View Article and Find Full Text PDF

Measurement of electrostatic tip-sample interactions by time-domain Kelvin probe force microscopy.

Beilstein J Nanotechnol

June 2020

Nanotechnology Group, ETH Zürich, Säumerstrasse 4, 8803 Rüschlikon, Switzerland.

Kelvin probe force microscopy is a scanning probe technique used to quantify the local electrostatic potential of a surface. In common implementations, the bias voltage between the tip and the sample is modulated. The resulting electrostatic force or force gradient is detected via lock-in techniques and canceled by adjusting the dc component of the tip-sample bias.

View Article and Find Full Text PDF

Water desorption in Kelvin-probe force microscopy: a generic model.

Nanotechnology

December 2018

Automation and Control Institute (ACIN), TU Wien, Gusshausstrasse 27-29, A-1040 Vienna, Austria. Department of Physics, King's College London, Strand, London WC2R 2LS, United Kingdom.

Nanoparticles or similar, nanoscale objects such as proteins or biological fibrils usually have to be deposited from aqueous suspension onto a solid support surface for further characterization by atomic force microscopy (AFM) and related methods such as Kelvin-probe force microscopy (KFM). Here we show, on the examples of functionalized nanoparticles and collagen fibrils, that water desorption after sample preparation affects their electrostatic potential determined by KFM in a predictable manner. We explain this effect with a simple, analytical model based on the capacitance of the partially dielectric-filled tip-sample system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!