AI Article Synopsis

Article Abstract

Aim: We aimed to compare the 18 and 16-Gauge (G) needles used in transrectal ultrasonography (TRUS)-guided needle biopsy for cancer detection rates and complications using the Clavien Scoring System.

Materials And Methods: The 80 patients who were included in the study were randomized and divided into two groups. Group 1 (n = 36) had a TRUS-guided prostate biopsy with an 18G needle and Group 2 had a 16G needle (n = 44). The hematuria, bleeding assessment, and infection events were evaluated on a daily basis. These complications were graded according to the Clavien Scoring.

Results: In Group 1, only five (13%) patients were diagnosed with prostate cancer, and three patients were reported to have atypical small acinar proliferation (ASAP). In Group 2, 16 (36%) patients were diagnosed with prostate cancer and one patient was reported to have ASAP. The difference in the prostate cancer detection rate between the groups was statistically significant. According to the Clavien grading system, the complications were at the Grade 1 level in 25 people in Group 1 in 29 people in Group 2. Grade 2 level complications were not observed in either group. While one person was Grade 3 in Group 1, two people in Group 2 had this rate. There were no significant differences between the groups.

Conclusions: We found that cancer detection rate increased by increasing the thickness of the needle used in TRUS-guided prostate biopsy without any increase in the complications.

Download full-text PDF

Source
http://dx.doi.org/10.5301/uj.5000238DOI Listing

Publication Analysis

Top Keywords

prostate cancer
16
cancer detection
12
people group
12
group
9
clavien scoring
8
trus-guided prostate
8
prostate biopsy
8
patients diagnosed
8
diagnosed prostate
8
detection rate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!