A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analytical Method for Pyrethroid Metabolites in Urine of the Non-Occupationally Exposed Population by Gas Chromatography/Mass Spectrometry. | LitMetric

Pyrethroids are widely being used as household insecticides or mothproof repellents. An analytical method is described for determination of urinary metabolites as biomarkers for monitoring exposure to the pyrethroids. In total, 11 urinary metabolites, 3-(2-carboxyprop-1-enyl)-2,2-dimethylcyclopropanecarboxylic acid, 3-(2-chloro-3,3,3-trifluoroprop-1-enyl)-2,2-dimethylcyclopropanecarboxylic acid, 3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropanecarboxylic acid, 2,2-dimethyl-3-(2-methylprop-1-enyl)cyclopropanecarboxylic acid, 4-fluoro-3-phenoxybenzoic acid, 4-methoxymethyl-2,3,5,6-tetrafluorobenzly alcohol, 2-methyl-3-phenylbenzoic acid, 4-methyl-2,3,5,6-tetrafluorobenzyl alcohol, 3-phenoxybenzoic acid, 2,3,5,6-tetrafluorobenzoic acid and 2,2,3,3-tetramethylcyclopropanecarboxylic acid, were enzymatically hydrolyzed and extracted with toluene. After transformation to their tert-butyldimethylsilyl or trimethylsilyl derivatives, they were analyzed by gas chromatography/mass spectrometry in electron impact ionization mode. The calibration curves for the metabolite were linear over the concentration range of 0-30 μg/L in urine. They could be determined accurately and precisely (detection limits: 0.01-0.12 μg/L, quantification limits: 0.04-0.41 μg/L). The urine samples collected could be stored for up to 1 month at -20°C in a freezer. The proposed method was applied to determine urine samples from several health volunteers. The method was considered to be available for monitoring pyrethroid exposure in the general population.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmx048DOI Listing

Publication Analysis

Top Keywords

acid
9
analytical method
8
gas chromatography/mass
8
chromatography/mass spectrometry
8
urinary metabolites
8
μg/l urine
8
urine samples
8
method pyrethroid
4
pyrethroid metabolites
4
urine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!