Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1126/science.aan1229 | DOI Listing |
The current study aimed to objectively evaluate the fit of a rectangular, tapered stem to the severely dysplastic hips on the basis of the proximal femoral anatomy and the dimensional properties of the stem. It was hypothesized that the stem size planned with accordance to the diaphyseal canal width alone can accommodate the distal femur successfully with no sizing mismatch. Forty-six patients (53 hips) suffering from secondary osteoarthritis due to hip dysplasia scheduled for total hip arthroplasty (THA) with a subtrochanteric transverse shortening osteotomy were included.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.
Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.
View Article and Find Full Text PDFGynecol Oncol
January 2025
University of Siena and Center for Immuno-Oncology, Department of Oncology, University Hospital, Siena, Italy. Electronic address:
Objective: We report updated results with longer follow-up in patients with MSI-H/dMMR endometrial cancer (EC) in cohort D (advanced EC of any MSI/dMMR status) and cohort K (any MSI-H/dMMR advanced solid tumor, except colorectal) of the phase 2 KEYNOTE-158 study (NCT02628067) and the first results from patients with non-MSI-H/non-dMMR advanced EC (cohort D).
Methods: Patients received pembrolizumab 200 mg Q3W for ≥35 cycles. The primary endpoint was objective response rate (ORR) per RECIST v1.
PLoS One
January 2025
Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada.
Lower-limb exoskeletons have demonstrated great potential for gait rehabilitation in individuals with motor impairments; however, maintaining human-exoskeleton coordination remains a challenge. The coordination problem, referred to as any mismatch or asynchrony between the user's intended trajectories and exoskeleton desired trajectories, leads to sub-optimal gait performance, particularly for individuals with residual motor ability. Here, we investigate the virtual energy regulator (VER)'s ability to generate coordinated locomotion in lower limb exoskeleton.
View Article and Find Full Text PDFClin Implant Dent Relat Res
February 2025
Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, Minnesota, USA.
Objectives: This study evaluated different designs of the conical implant-abutment connection (IAC) and their resistance to microgap formation under oblique loads as specified by the ISO standard for testing dental implants. Also evaluated was the effect of deviations from the ISO specifications on the outcomes.
Methods: Finite element analysis was conducted to compare the microgap formation and stress distribution among three conical IAC designs (A, B, and C) in two loading configurations: one compliant with ISO 14801 and one with a modified load adaptor (non-ISO).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!