Background: A quantitative analysis comparing indocyanine green videoangiography (ICG-VAG) and fluorescein videoangiography (FL-VAG) in cerebrovascular surgery has not been reported so far.

Objective: To clear the differences of characteristics of ICG-VAG and FL-VAG by quantitative assessment.

Methods: We prospectively analyzed results from 23 patients (3 males; mean age at surgery: 60.9 years, range: 14-75 years) at our hospital from August 2014 to July 2015. Eighteen patients had cerebral aneurysms for clipping, and 5 had intracranial arterial stenosis for superficial temporal artery (STA)-middle cerebral artery bypass. We imported data from the operative image data, converted by Audio Video Interleave to Aquacosmos as picture fluorescence intensity-analyzing software. Regions of interest were set at the parent artery, dome of aneurysms, and perforating artery in cases of clipping of aneurysms, and setting at 3 points in STA, in case of bypass. The transition of fluorescence intensity at each region of interest was calculated and plotted using Aquacosmos.

Results: Thick-walled artery, such as parent artery ( P = .0017) and STA ( P = .0182), was more significantly visualized by ICG-VAG than FL-VAG, whereas the perforating artery, especially in deep surgical fields, such as anterior communicating artery, internal carotid artery, and basilar artery, was better visualized by FL-VAG than ICG-VAG ( P < .0001).

Conclusion: In this quantitative analysis of fluorescence study, ICG-VAG showed greater efficacy than FL-VAG in visualizing relatively thick arteries, such as parent artery and STA. However, FL-VAG has greater efficacy than ICG-VAG in visualizing perforating artery, especially in deep surgical fields with characteristic vessel walls.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ons/opw020DOI Listing

Publication Analysis

Top Keywords

artery
12
parent artery
12
perforating artery
12
indocyanine green
8
cerebrovascular surgery
8
quantitative analysis
8
icg-vag fl-vag
8
artery deep
8
deep surgical
8
surgical fields
8

Similar Publications

Fluid administration is widely used to treat hypotension in patients undergoing veno-venous extracorporeal membrane oxygenation (VV-ECMO). However, excessive fluid administration may lead to fluid overload can aggravate acute respiratory distress syndrome (ARDS) and increase patient mortality, predicting fluid responsiveness is of great significance for VV-ECMO patients. This prospective single-center study was conducted in a medical intensive care unit (ICU) and finally included 51 VV-ECMO patients with ARDS in the prone position (PP).

View Article and Find Full Text PDF

Objective: Here, we aim to investigate whether D-dimer (DD)/fibrinogen (FIB) ratio or combination of DD and FIB contribute to the prognosis of stroke and stroke subtypes.

Methods: 1413 patients with acute ischemic stroke (AIS) were recruited. We measured DD and FIB levels on admission and followed up with patients at discharge and 90-day following discharge.

View Article and Find Full Text PDF

Background: Enhanced Recovery After Surgery (ERAS) protocols can reduce the length of stay (LOS) for surgical patients, including those undergoing unilateral deep inferior epigastric artery perforator (DIEP) flap breast reconstruction, allowing most patients to be discharged by postoperative day 2. However, some patients require a prolonged inpatient stay due to difficulty completing postoperative milestones. This study aims to identify factors associated with increased LOS after DIEP flap breast reconstruction and assess safety of earlier discharge.

View Article and Find Full Text PDF

Template-Assisted Electrospinning and 3D Printing of Multilayered Hierarchical Vascular Grafts.

J Biomed Mater Res B Appl Biomater

January 2025

Department of Polymer and Biomaterials Science, Faculty of Chemical Technology and Engineering, West Pomeranian University of Technology in Szczecin, Szczecin, Poland.

Fabricating complex hierarchical structures mimicking natural vessels and arteries is pivotal for addressing problems of cardiovascular diseases. Various fabrication strategies have been explored to achieve this goal, each contributing unique advantages and challenges to the development of functional vascular grafts. In this study, a three-layered tubular structure resembling vascular grafts was fabricated using biocompatible and biodegradable copolymers of poly(butylene succinate) (PBS) using advanced manufacturing techniques.

View Article and Find Full Text PDF

Introduction: The efficacy of lipoprotein apheresis (LA) in peripheral arterial disease (PAD) has been primarily attributed to its anti-atherosclerotic effects through the adsorption of lipoproteins. However, the other potential effects of LA remain unknown. We evaluated changes in serum profiles before and after LA using a comprehensive analysis to explore the underlying mechanism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!