Introduction: An online Magnetic Resonance guided Radiation Therapy (MRgRT) system is under development. The system is comprised of an MRI with the capability of travel between and into HDR brachytherapy and external beam radiation therapy vaults. The system will provide on-line MR images immediately prior to radiation therapy. The MR images will be registered to a planning image and used for image guidance. With the intention of system safety we have performed a failure modes and effects analysis.
Methods: A process tree of the facility function was developed. Using the process tree as well as an initial design of the facility as guidelines possible failure modes were identified, for each of these failure modes root causes were identified. For each possible failure the assignment of severity, detectability and occurrence scores was performed. Finally suggestions were developed to reduce the possibility of an event.
Results/discussion: The process tree consists of nine main inputs and each of these main inputs consisted of 5 - 10 sub inputs and tertiary inputs were also defined. The process tree ensures that the overall safety of the system has been considered. Several possible failure modes were identified and were relevant to the design, construction, commissioning and operating phases of the facility. The utility of the analysis can be seen in that it has spawned projects prior to installation and has lead to suggestions in the design of the facility.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.4740112 | DOI Listing |
Sci Rep
January 2025
College of Mining Engineering, Taiyuan University of Technology, Taiyuan, 030024, Shanxi Province, China.
The influence of interface morphology is of great importance on the shear behavior of the cement mortar-coal composite structure (CCCS) widely distributed in underground mines. In the present research, both the macroscopic- and microscopic failure characteristics of the CCCS with variable interface sawtooth angles (i.e.
View Article and Find Full Text PDFEur J Vasc Endovasc Surg
January 2025
Aortic Center, Hôpital Marie Lannelongue, GHPSJ, Le Plessis-Robinson, France. Electronic address:
Objective: The aim of this study was to perform a comparative pre-clinical evaluation of a new fenestrated endovascular aneurysm repair dedicated stent using perfused 3D printed patient anatomies.
Methods: The test setup included a pulsatile pump set to reproduce human haemodynamics, four 3D printed pararenal aneurysms connected to a bench test, and four corresponding fenestrated grafts (Zenith Fenestrated; Cook, Bloomington, IN, USA). Bridging stents were sized based on analysis of patients computed tomography scans and included either four standard covered stents (BeGraft [BG]; Bentley, Hechingen, Germany) or four similar covered stent grafts mounted on a modified balloon to allow stent implantation and flaring in one step (BeFlared [BF]; Bentley).
BMC Med
January 2025
Department of Anaesthesiology, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria.
Background: Patients at need for ventilation often are at risk of acute respiratory distress syndrome (ARDS). Although lung-protective ventilation strategies, including low driving pressure settings, are well known to improve outcomes, clinical practice often diverges from these strategies. A clinical decision support (CDS) system can improve adherence to current guidelines; moreover, the potential of a CDS to enhance adherence can possibly be further increased by combination with a nudge type intervention.
View Article and Find Full Text PDFJ Contemp Dent Pract
October 2024
College of Dentistry, Ajman University, Ajman P.O. Box 346, United Arab Emirates; Department of Endodontic, Faculty of Dentistry, Mansoura University, Egypt, Orcid: https://orcid.org/0000-0003-3391-5306.
Aim: This study aimed to investigate and compare the total and sectional bond strengths of three endodontic sealers when used with the single-cone obturation technique.
Materials And Methods: Forty-five human maxillary central incisors were prepared and divided into three groups according to the type of endodontic sealer: Group I (Gutta-percha/AH Plus Jet), group II (Gutta-percha/GuttaFlow 2), and group III (RealSeal/RealSeal SE). All canals were filled with the single-cone technique.
J Prosthodont
January 2025
Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine; College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology; Shanghai Research Institute of Stomatology, Shanghai, PR China.
Purpose: To evaluate the shear bond strength (SBS) of stereolithography (SLA), digital light processing (DLP) manufactured, and computer numerical control (CNC) milled zirconia to veneering ceramic.
Materials And Methods: Rectangular shaped zirconia substrates (10 × 5 × 5 mm) were manufactured through SLA, DLP, and CNC technology separately. Their surface roughness was measured and the surface topography was analyzed by atomic force microscope (AFM).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!