The purpose of this paper is to summarize the need, feasibility, safety, legality, and ethical perspectives of pacemaker reutilization in low- and middle-income countries (LMICs). It will also describe, in-depth, Project My Heart Your Heart (PMHYH) as a model for pacemaker reuse in LMICs. The primary source of the discussion points in this paper is a collection of 14 publications produced by the research team at the University of Michigan and its collaborative partners. The need for pacemaker reutilization in LMICs is evident. Numerous studies show that the concept of pacemaker reutilization in LMICs is feasible. Infection and device malfunction are the main concerns in regard to pacemaker reutilization, yet many studies have shown that pacemaker reuse is not associated with increased infection risk or higher mortality compared with new device implantation. Under the right circumstances, the ethical and legal bases for pacemaker reutilization are supported. PMHYH is a proof of concept pacemaker donation initiative that has allowed funeral home and crematory directors to send explanted devices to an academic center for evaluation and re-sterilization before donation to underserved patients in LMICs. The time is now to pursue large-scale studies and trials of pacemaker reuse for the betterment of society. PMHYH is leading the way in the effort and is poised to conduct a prospective randomized, non-inferiority, multicenter study to confirm the clinical efficacy and safety of pacemaker reuse, for clinical and legal support.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5411963 | PMC |
http://dx.doi.org/10.4330/wjc.v9.i4.296 | DOI Listing |
J Interv Card Electrophysiol
August 2023
Nursing Department I, Faculty of Medicine and Nursing, University of the Basque Country UPV/EHU, Sarriena, Leioa, Spain.
Background: Postmortem explanted cardiac implantable electronic devices (CIEDs) from developed countries could provide patients unable to afford new devices in low- and middle-income countries (LMIC) a treatment they lack. This study describes the preferences of electrophysiologists and device implanting cardiologists from Spain on the management of explanted CIEDs and opinions and concerns regarding reuse in LMIC.
Methods: A nationwide self-administered questionnaire was sent to members of the Spanish Rhythm Association (n = 1110), between December 2020 and January 2021.
J Cardiovasc Electrophysiol
March 2022
Department of Internal Medicine, Michigan Medicine, University of Michigan, Ann Arbor, Michigan, USA.
Introduction: The reuse of cardiac implantable electronic devices may help increase access to these therapies in low- and middle-income countries (LMICs). No published data exist regarding the views of patients and family members in LMICs regarding this practice.
Methods And Results: An article questionnaire eliciting attitudes regarding pacemaker reuse was administered to ambulatory adult patients and patients' family members at outpatient clinics at Centro Nacional Cardiologia in Managua, Nicaragua, Indus Hospital in Karachi, Pakistan, Hospital Carlos Andrade Marín, and Hospital Eugenio Espejo in Quito, Ecuador, and American University of Beirut Medical Center in Beirut, Lebanon.
World J Cardiol
April 2017
Mason W Runge, Kim A Eagle, Thomas C Crawford, Department of Internal Medicine, University of Michigan, Ann Arbor, MI 48109, United States.
The purpose of this paper is to summarize the need, feasibility, safety, legality, and ethical perspectives of pacemaker reutilization in low- and middle-income countries (LMICs). It will also describe, in-depth, Project My Heart Your Heart (PMHYH) as a model for pacemaker reuse in LMICs. The primary source of the discussion points in this paper is a collection of 14 publications produced by the research team at the University of Michigan and its collaborative partners.
View Article and Find Full Text PDFPacing Clin Electrophysiol
August 2014
University of Michigan Cardiovascular Center, Ann Arbor, Michigan.
Background: Reuse of cardiac implantable electronic devices (CIEDs) may help address the unmet need among patients in low- and middle-income countries (LMICs).
Methods: To examine Heart Rhythm Society (HRS) physicians' opinions regarding CIED reuse, an online survey eliciting attitudes toward CIED reuse was sent to all 3,380 HRS physician members.
Results: There were 429 responses (response rate 13%).
Dev World Bioeth
December 2015
According to the World Health Organization (WHO) cardiovascular disease (CVD) is the leading cause of death globally. Over 80% of CVD deaths take place in low- and middle-income countries (LMICs). It is estimated that 1 million to 2 million people worldwide die each year due to lack of access to an implantable cardiac defibrillator (ICD) or a pacemaker.