Introduction: We performed this study to investigate whether the SEDline system, a 4-channel-processed electroencephalography (EEG) monitoring device in the frontal area, can detect epileptiform discharges accurately during post-resuscitation care in comatose cardiac arrest survivors.
Methods: Adult comatose cardiac arrest survivors, who were admitted to the intensive care unit (ICU) for post-resuscitation care including TTM, were enrolled. Within 72h post-return of spontaneous circulation (ROSC), conventional EEG was conducted for 30min. The SEDline system data were recorded with a video camera simultaneously with conventional EEG. Data retrieved from conventional EEG were interpreted by a neurologist and data from the SEDline system were interpreted by three emergency physicians blinded to the conventional EEG data. Then, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the SEDline system to detect epileptiform discharges were calculated.
Results: Thirty-nine patients were enrolled in this study. Epileptiform discharges were confirmed in 6 patients (15.4%) who had the same patterns of generalized periodic epileptiform discharges in both conventional EEG and the concurrent SEDline system. The SEDline system showed 100.0% (95% confidence interval (CI), 54.1-100.0%) of sensitivity, 100.0% (95% CI, 89.4-100.0%) of specificity, 100.0% (95% CI, 54.1-100.0%) of PPV, and 100.0% (95% CI, 89.4-100.0%) of NPV. The overall classification accuracy of the SEDline system to detect epileptiform discharges was 100.0%.
Conclusion: The SEDline system detected epileptiform discharges accurately in comatose cardiac arrest survivors during post-resuscitation care.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.resuscitation.2017.05.016 | DOI Listing |
Anesth Analg
August 2024
From the Department of Anesthesiology and Intensive Care, School of Medicine and Health, Technical University of Munich, Munich, Germany.
Background: The electroencephalographic (EEG) provides the anesthesiologist with information regarding the level of anesthesia. Processed EEG indices are available that reflect the level of anesthesia as a single number. Strong oscillatory EEG activity in the alpha-band may be associated with an adequate level of anesthesia and a lower incidence of cognitive sequelae.
View Article and Find Full Text PDFJ Neurosurg Anesthesiol
March 2024
Department of Anesthesiology, Columbia University Vagelos College of Physicians & Surgeons, New York, NY.
Background: Frontal electroencephalography (EEG) monitoring can be useful in guiding the titration of anesthetics, but it is not always feasible to place electrodes in the standard configuration in some circumstances, including during neurosurgery. This study compares 5 alternate configurations of the Masimo Sedline Sensor.
Methods: Ten stably sedated patients in the intensive care unit were recruited.
J Anesth Analg Crit Care
February 2024
Department of Psychiatry, VA Boston Healthcare System, Harvard Medical School, Boston, MA, USA.
Background: Electroconvulsive therapy (ECT) endures as a definitive treatment for refractory depression and catatonia and is also considered an effective treatment for a number of other severe psychiatric disorders (Lisanby, N Engl J Med 357:1939-1945, 2007)(Weiner and Prudic, Biol Psychiatry 73:105-106, 2013). GA is an essential component of the ECT procedure for various reasons (Lee, Jenkins and Sparkle, Life 11, 2021). Monitoring anesthetic effects on the brain is desirable as anesthetic agents affect seizure duration and recovery (Rasulo, Hopkins, Lobo, et al, Neurocrit Care 38:296-311, 2023) (Jones , Nittur , Fleming and Applegate, BMC Anesthesiol 21:105, 2021) (Soehle , Kayser , Ellerkmann and Schlaepfer, BJA 112:695-702, 2013).
View Article and Find Full Text PDFHeliyon
January 2024
Department of Anesthesiology, First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China.
Background: Postoperative delirium (POD) is a common complication following cardiac surgery and increases postoperative morbidity and mortality. Intraoperative electroencephalogram (EEG) burst suppression suggests excessively deep anesthesia and predicts POD. Use of remimazolam provides a stable hemodynamic status and an appropriate depth of anesthesia.
View Article and Find Full Text PDFCureus
October 2023
Department of Anesthesiology, Cooper University Hospital, Camden, USA.
Background: Propofol sedation is commonly administered during gastrointestinal (GI) procedures. The Patient State Index (PSI) is a processed electroencephalography (EEG) parameter obtained with the SedLine Sedation Monitoring system (Masimo Corporation, Irvine, CA). When used to objectively assess the patient's level of consciousness, PSI may provide a more effective, safer titration of sedation during GI procedures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!