Objective: Pauwels III femoral neck fractures are highly unstable. These fractures are commonly treated with three cannulated screws or sliding hip screw (SHS) implants, however high rates of non-union persist. A hybrid SHS construct has recently been proposed. The objective of the study was to compare this construct to the familiar inverted triad of cannulated screws and to a single SHS.
Methods: Fourth generation biomechanical femur analogs were used to create a highly repeatable injury model. The hybrid SHS construct contained a SHS with two superior cannulated screws in an inverted triangle configuration. Eight samples for each construct were biomechanically evaluated and the results compared using ANOVA (p<0.05).
Results: The cannulated triad and hybrid SHS provided similar stiffness and fracture gap motion. The single SHS exhibited significantly lower stiffness and larger fracture plane diastasis than either the inverted triangle of cannulated screws or hybrid SHS (p<0.05). None of the constructs exhibited catastrophic failure during cyclic loading nor under loading up to 2.5 times body weight.
Conclusions: The single SHS provided the least stable fracture fixation, while the inverted triad and hybrid SHS constructs were mechanically similar. The fracture repair simulated here illustrates how these repairs have the potential to return near pre-fracture strength in ideal conditions with young, healthy bone. However; in clinical situations where comminution impairs load transfer through the cortices the hybrid SHS may be the most favorable option.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.injury.2017.05.013 | DOI Listing |
Injury
January 2025
Royal College of Surgeons in Ireland, Dublin, Ireland. Electronic address:
Background: Femoral neck fractures, particularly Pauwels type II and III, pose significant challenges due to their vertical instability and susceptibility to complications such as non-union and avascular necrosis (AVN). Medial buttress plates (MBPs) have emerged as a promising adjunct in fixation, offering biomechanical advantages by neutralizing shearing forces and enhancing stability. However, the clinical efficacy of MBPs across different fixation techniques, plate configurations, and positioning remains unclear.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Orthopedics, First Affiliated Hospital of Dalian Medical University, Dalian, 116011, Liaoning Province, China.
Objective: This study aimed to evaluate the clinical effectiveness of the femoral neck system (FNS) compared to four cannulated compression screws (CCSs) for managing Pauwels type III femoral neck fractures in young patients.
Methods: A retrospective analysis was conducted on young patients with Pauwels type III femoral neck fractures treated at our hospital from January 2021 to December 2022. Patients were categorized into two groups based on their respective internal fixation methods: the FNS group (32 cases) and the CCSs group (41 cases).
J Orthop Case Rep
January 2025
Department of Orthopaedics, Vinayaka Mission's Medical College and Hospital, Vinayaka Mission's Research Foundation (DU), Karaikal , Puducherry, India.609609.
Introduction: Extreme beak calcaneal fractures (Type 2 Lee's tuberosity avulsion fractures) are rare injuries, accounting for only 1.3-3% of all calcaneal fractures. These injuries are considered as surgical emergency as they can lead to significant functional impairment and soft-tissue compromise if not promptly managed.
View Article and Find Full Text PDFJ Orthop Case Rep
January 2025
Department of Orthopaedics, SN Medical College, Agra, Uttar Pradesh, India.
Introduction: Posterior cruciate ligament (PCL) avulsion fractures of the tibia with ipsilateral tibial shaft represent a rare but challenging orthopedic injury, necessitating careful consideration of surgical interventions for optimal outcomes. This case report presents the successful management of tibial shaft fracture (proximal 1/3rd junction) along with ipsilateral PCL avulsion fracture of tibia using a novel approach using open reduction internal fixation (ORIF) of tibial shaft with Locking compression plate (LCP) with cannulated cancellous screw and spiked washer fixation of PCL avulsion. There are no case reports or research articles available for the management of PCL avulsion fracture of tibia associated with ipsilateral tibial shaft fracture.
View Article and Find Full Text PDFAnimals (Basel)
December 2024
Department of Veterinary Medicine, Kangwon National University, Chuncheon-si 24341, Gangwon-do, Republic of Korea.
A 3D-printed guide is an effective method for accurately placing pedicle screws in dog vertebrae. While a conventional drill guide allows precise pilot hole formation, it can lead to potential screw wobbling during insertion. In this study, we applied a technique that assists with both drilling and screw insertion, and we compared the accuracy of screw placement using this approach with that achieved by the conventional drill guide.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!