Purpose: The aim of this study was to compare a medical-grade PACS (picture archiving and communication system) monitor, a consumer-grade monitor, a laptop computer, and a tablet computer for linear measurements of height and width for specific implant sites in the posterior maxilla and mandible, along with visualization of the associated anatomical structures.
Material And Methods: Cone beam computed tomography (CBCT) scans were evaluated. The images were reviewed using PACS-LCD monitor, consumer-grade LCD monitor using CB-Works software, a 13″ MacBook Pro, and an iPad 4 using OsiriX DICOM reader software. The operators had to identify anatomical structures in each display using a 2-point scale. User experience between PACS and iPad was also evaluated by means of a questionnaire.
Results: The measurements were very similar for each device. P-values were all greater than 0.05, indicating no significant difference between the monitors for each measurement. The intraoperator reliability was very high. The user experience was similar in each category with the most significant difference regarding the portability where the PACS display received the lowest score and the iPad received the highest score.
Conclusions: The iPad with retina display was comparable with the medical-grade monitor, producing similar measurements and image visualization, and thus providing an inexpensive, portable, and reliable screen to analyze CBCT images in the operating room during the implant surgery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ID.0000000000000595 | DOI Listing |
Strahlenther Onkol
January 2025
TUM School of Medicine and Health, Department of Radiation Oncology, Technische Universität München (TUM), Klinikum rechts der Isar, Munich, Germany.
Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.
View Article and Find Full Text PDFJ Contemp Dent Pract
September 2024
RAK College of Dental Sciences, RAK Medical and Health Sciences University, Ras Al Khaimah, United Arab Emirates.
Aim: The aim of this cross-sectional prospective study was to evaluate the bone density changes around the bicortical corticobasal implant placed in the maxilla over 18 months of follow-up using cone-beam computed tomography (CBCT), focusing on the comparison between the anterior and posterior teeth and regions.
Materials And Methods: Thirty-five subjects (20, 53.26%, were males, and 15, 46.
Ann Thorac Surg Short Rep
December 2024
Department of Thoracic and Cardiovascular Surgery, Osaka Medical and Pharmaceutical University, Osaka, Japan.
Background: We have developed a new hybrid warp-knit fabric for induction of in situ tissue regeneration that has shown appropriate antideterioration properties and expandability in preclinical studies. This study was performed to assess the clinical efficacy and safety of this fabric in the early postoperative period after congenital cardiac surgery.
Methods: The fabric comprises biodegradable (complete degradation period, 2-3 years) and nonbiodegradable yarns coated with cross-linked gelatin.
Ear Hear
January 2025
Department of Otorhinolaryngology and Head and Neck Surgery, Radboud University Medical Centre, Donders Institute for Brain, Cognition and Behaviour, Nijmegen, The Netherlands.
Objectives: Real-time monitoring of cochlear function to predict the loss of residual hearing after cochlear implantation is now possible. Current approaches monitor the cochlear microphonic (CM) during implantation from the electrode at the tip of the implant. A drop in CM response of >30% is associated with poorer hearing outcomes.
View Article and Find Full Text PDFBiomaterials
January 2025
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States; Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States. Electronic address:
Intracortical microelectrodes (IMEs) are essential for neural signal acquisition in neuroscience and brain-machine interface (BMI) systems, aiding patients with neurological disorders, paralysis, and amputations. However, IMEs often fail to maintain robust signal quality over time, partly due to neuroinflammation caused by vascular damage during insertion. Platelet-inspired nanoparticles (PIN), which possess injury-targeting functions, mimic the adhesion and aggregation of active platelets through conjugated collagen-binding peptides (CBP), von Willebrand Factor-binding peptides (VBP), and fibrinogen-mimetic peptides (FMP).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!