Objective: To evaluate the performance of a simple semi-automated method for estimation of fetal weight (EFW) using magnetic resonance imaging (MRI) as compared with two-dimensional (2D) ultrasound (US) for the prediction of large-for-dates neonates.

Methods: Data of two groups of women with singleton pregnancy between March 2011 and May 2016 were retrieved from our database and evaluated retrospectively: the first group included women who underwent US-EFW and MRI-EFW within 48 h before delivery and the second group included women who had these evaluations between 35 + 0 weeks and 37 + 6 weeks of gestation, more than 48 h before delivery. US-EFW was based on Hadlock et al. and MRI-EFW on the formula described by Baker et al. For MRI-EFW, planimetric measurement of the fetal body volume (FBV) was performed using a semi-automated method and the time required for measurement was noted. Outcome measure was the performance of MRI-EFW vs US-EFW in the prediction of large-for-dates neonates, both ≤ 48 h and > 48 h before delivery. Receiver-operating characteristics (ROC) curves for each method were compared using the DeLong method.

Results: Of the 270 women included in the first group, 48 (17.8%) newborns had birth weight ≥ 90 centile and 30 (11.1%) ≥ 95 centile. The second group included 83 women, and nine (10.8%) newborns had birth weight ≥ 95 centile. Median time needed for FBV planimetric measurements in all 353 fetuses was 3.5 (range, 1.5-5.5) min. The area under the ROC curve (AUC) for prediction of large-for-dates neonates by prenatal MRI performed within 48 h before delivery was significantly higher than that by US (for birth weight ≥ 90 centile, difference between AUCs = 0.085, standard error (SE) = 0.020, P < 0.001; for birth weight ≥ 95 centile, difference between AUCs = 0.036, SE = 0.014, P = 0.01). Similarly, MRI-EFW was better than US-EFW in predicting birth weight ≥ 95 centile when both examinations were performed > 48 h prior to delivery (difference between AUCs = 0.077, SE = 0.039, P = 0.045).

Conclusion: MRI planimetry using our purpose-designed semi-automated method is not time-consuming. The predictive performance of MRI-EFW performed immediately prior to or remote from delivery is significantly better than that of US-EFW for the prediction of large-for-dates neonates. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

Download full-text PDF

Source
http://dx.doi.org/10.1002/uog.17523DOI Listing

Publication Analysis

Top Keywords

large-for-dates neonates
16
prediction large-for-dates
16
semi-automated method
12
group included
12
included women
12
48 h delivery
12
second group
8
performance mri-efw
8
us-efw prediction
8
newborns birth
8

Similar Publications

Induction of labour at or near term for suspected fetal macrosomia.

Cochrane Database Syst Rev

March 2023

Division of Child Health, Obstetrics and Gynaecology, School of Medicine, University of Nottingham, Nottingham, UK.

Background: Women with a suspected large-for-dates fetus or a fetus with suspected macrosomia (birthweight greater than 4000 g) are at risk of operative birth or caesarean section. The baby is also at increased risk of shoulder dystocia and trauma, in particular fractures and brachial plexus injury. Induction of labour may reduce these risks by decreasing the birthweight, but may also lead to longer labours and an increased risk of caesarean section.

View Article and Find Full Text PDF

Objective: To evaluate the performance of a simple semi-automated method for estimation of fetal weight (EFW) using magnetic resonance imaging (MRI) as compared with two-dimensional (2D) ultrasound (US) for the prediction of large-for-dates neonates.

Methods: Data of two groups of women with singleton pregnancy between March 2011 and May 2016 were retrieved from our database and evaluated retrospectively: the first group included women who underwent US-EFW and MRI-EFW within 48 h before delivery and the second group included women who had these evaluations between 35 + 0 weeks and 37 + 6 weeks of gestation, more than 48 h before delivery. US-EFW was based on Hadlock et al.

View Article and Find Full Text PDF

Induction of labour at or near term for suspected fetal macrosomia.

Cochrane Database Syst Rev

May 2016

Département de Gynécologie et d'Obstétrique, Unité de Développement en Obstétrique, Maternité Hôpitaux Universitaires de Genève, Boulevard de la Cluse, 32, Genève 14, Switzerland, CH-1211.

Editorial Note: It has been brought to the authors' attention that there may be an error in the data (Analysis 1.9). This is currently under investigation, and a correction will be made if the data are found to be incorrect.

View Article and Find Full Text PDF

Association of gestational weight gain and pre-pregnancy body mass index with adverse pregnancy outcome.

J Coll Physicians Surg Pak

November 2012

Department of Obstetrics and Gynaecology, The Aga Khan University Hospital, Stadium Road, Karachi.

Objective: To determine the association between gestation weight gain (GWG) and adverse pregnancy outcome in a Pakistani population.

Study Design: Analytical study.

Place And Duration Of Study: The Aga Khan University, Karachi, from February 2003 to 2007.

View Article and Find Full Text PDF

Objective: To determine the frequency of impaired oral glucose tolerance test in high risk pregnancies for Gestational Diabetes Mellitus (GDM).

Study Design: Cross-sectional study.

Place And Duration Of Study: The study was conducted in Obstetric Ward and outpatient department, at Baqai Hospital, Nazimabad and Fatima Hospital, Baqai Medical University, Karachi, from May to October 2005.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!